4. Setting up the device
14
Display flashing,
FLASH:
A display flashing can be added as additional alarm function either to single or to a
combination of off-limit condition. With
no
, no flashing is allocated.
Assignment (deposit) of key functions,
tASt:
For the operation mode, special functions can be deposited on the navigation keys
[
▲
] [
▼
], in particular this function is made for devices in housing size 48x24 which do
not have a 4th key (
[O]
key). If the min-/max-memory is activated with
EHtr
, all
measured min/nax-values are safed during operation and can be recalled via the
navigation keys. The values get lost by re-start of the device. If the threshold value
correction
LI.12
or
LI.34
is choosen, the values of the threshold can be changed during
operation without disturbing the operating procedure. With
tArA
the device is tared to
zero and safed permanently as offset. The device confirms the correct taring by
showing
ooooo
in the display.
Set.tA
switches into the offset value and can be changed
via the navigation keys [
▲
] [
▼
].
Display,
dISPL:
With this function the current measuring value, min-/max-value, totaliser value or the
process-controlled hold-value can be allocated to the display. With
[P]
the selection is
confirmed and the device changes into menu level.
Zero point slowdown,
ZErO:
At the zero point slowdown, a value range around the zero point can be preset, so the
display shows a zero. If e.g. a 10 is set, the display would show a zero in the value
range from -10 to +10; below continue with -11 and beyond with +11. The maximum
adjustable range of value is 99.
Parameterisation level
Menu level