Param-
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
8-90
Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
67
Uint16
8-91
Bus Jog 2 Speed
ExpressionLimit
All set-ups
TRUE
67
Uint16
8-94
Bus Feedback 1
0 N/A
1 set-up
TRUE
0
N2
8-95
Bus Feedback 2
0 N/A
1 set-up
TRUE
0
N2
8-96
Bus Feedback 3
0 N/A
1 set-up
TRUE
0
N2
4.1.10 9-** PROFIdrive
Param-
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
9-00
Setpoint
0 N/A
All set-ups
TRUE
0
Uint16
9-07
Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
9-15
PCD Write Configuration
ExpressionLimit
1 set-up
TRUE
-
Uint16
9-16
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
9-18
Node Address
126 N/A
1 set-up
TRUE
0
Uint8
9-22
Telegram Selection
[100] None
1 set-up
TRUE
-
Uint8
9-23
Parameters for Signals
0
All set-ups
TRUE
-
Uint16
9-27
Parameter Edit
[1] Enabled
2 set-ups
FALSE
-
Uint16
9-28
Process Control
[1] Enable cyclic
master
2 set-ups
FALSE
-
Uint8
9-31
Safe Address
0 N/A
1 set-up
TRUE
0
Uint16
9-44
Fault Message Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-45
Fault Code
0 N/A
All set-ups
TRUE
0
Uint16
9-47
Fault Number
0 N/A
All set-ups
TRUE
0
Uint16
9-52
Fault Situation Counter
0 N/A
All set-ups
TRUE
0
Uint16
9-53
PROFIBUS Warning Word
0 N/A
All set-ups
TRUE
0
V2
9-63
Actual Baud Rate
[255] No baudrate
found
All set-ups
TRUE
-
Uint8
9-64
Device Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-65
Profile Number
0 N/A
All set-ups
TRUE
0
OctStr[2]
9-67
Control Word 1
0 N/A
All set-ups
FALSE
0
V2
9-68
Status Word 1
0 N/A
All set-ups
TRUE
0
V2
9-70
Programming Set-up
[9] Active Set-up
All set-ups
TRUE
-
Uint8
9-71
PROFIBUS Save Data Values
[0] Off
All set-ups
TRUE
-
Uint8
9-72
ProfibusDriveReset
[0] No action
1 set-up
FALSE
-
Uint8
9-75
DO Identification
0 N/A
All set-ups
TRUE
0
Uint16
9-80
Defined Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-81
Defined Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-82
Defined Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-83
Defined Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-84
Defined Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-85
Defined Parameters (6)
0 N/A
All set-ups
FALSE
0
Uint16
9-90
Changed Parameters (1)
0 N/A
All set-ups
FALSE
0
Uint16
9-91
Changed Parameters (2)
0 N/A
All set-ups
FALSE
0
Uint16
9-92
Changed Parameters (3)
0 N/A
All set-ups
FALSE
0
Uint16
9-93
Changed Parameters (4)
0 N/A
All set-ups
FALSE
0
Uint16
9-94
Changed Parameters (5)
0 N/A
All set-ups
FALSE
0
Uint16
9-99
PROFIBUS Revision Counter
0 N/A
All set-ups
TRUE
0
Uint16
Parameter Lists
Programming Guide
MG20OB02
Danfoss A/S © 05/2018 All rights reserved.
261
4
4