174
AK2-SC 255 Reference Manual
RS.8D.M1.22
form Normal Refrigeration to Cleaning Shutdown, the status of the lights, fans,
and anti-sweat heaters is automatically changed so that lights and fans are kept on
and anti-sweats are kept off until the fixture is returned to the normal refrigeration
mode.
2 - 4. Using the Refrigeration Screens for Refrigeration Circuits
Controlled directly from AK2-SC 255’s
The status screens for refrigeration circuits controlled directly from SC 255’s contain
different information than those for circuits with Smart Case Controllers.
Evaporator Status
Screen
The status screen for an SC 255 circuit is reached from the main menu by selecting
Refrigeration, then the Rack, then Evaporators, then the evaporator. Here’s the
status screen for an SC 255 circuit:
The status of the circuit is given in the first line. Possible contents are:
Thermostat Cutin:
The circuit is being refrigerated. Refrigeration is on
because the discharge air temperature reached
target temperature plus the temperature range.
Thermostat Cutout:
Refrigeration is off because the discharge air tem-
perature has reached target temperature minus the
temperature range.
Terminated Defrost:
Defrost has terminated and the circuit is in its drip
down period (if any).
Summary of Contents for AK2-SC 255
Page 1: ...REFRIGERATION AND AIR CONDITIONING AK2 SC 255 Reference Manual Users Manual...
Page 2: ...RS 8D M1 22 AK2 SC 255 Reference Manual 1 AK2 SC 255 Rack Controller System Reference Manual...
Page 3: ...2 AK2 SC 255 Reference Manual RS 8D M1 22...
Page 11: ...10 AK2 SC 255 Reference Manual RS 8D M1 22...
Page 157: ...156 AK2 SC 255 Reference Manual RS 8D M1 22...
Page 204: ...RS 8D M1 22 AK2 SC 255 Reference Manual 203...