System error
The relay is switched in case of certain errors in the complete system or if status messages
of a system component arrive at the recorder.
• camera failure
• write or read fault error of a HDD
• unknown software problem, recorder does not react or reacts only very slowly
• Housekeeping error event
• Error message of UPS
• Initialization error
• RAID (internal) error
The relay is held until the system error is eliminated.
The time for which the relay is held can also be set via the
Timer
.
Note:
The behavior of the relay corresponds to the
Error LED
of the recorder.
Start recording by image comparison event
The relay is switched if recording of a camera is triggered by motion detection.
The time for which the relay is held must be set via the Timer (e.g. 1 second).
More than 80% of a track occupied
This function does not make any sense under the standard configuration since tracks are
defined as ring buffers, and therefore cannot be overwritten. The definition of a track as
permanent storage and of the corresponding percent value is done by changing internal
parameters. Please contact the Dallmeier support team, if necessary.
This function switches the relay if more than X% of the reserved disk space of a track (per-
manent storage) are occupied.
The relay is held until the track is deleted.
The time for which the relay is held can also be set via the
Timer
.
More that 80% of the secure tracks occupied
This function switches the relay if more the 80% of the defined/reserved secure tracks have
been protected against overwriting.
The relay is held until a sufficient number of tracks has been released.
The time for which the relay is held can also be set via the
Timer
.
Start recording by image Contact IN
This relay is switched if the recording of a camera is triggered by a Contact IN function
(Start recording camera (recording mode Contact)
.
The time for which the relay is held must be set via the
Timer
(e.g. 1 second).
Error on writing/reading onto HDD
The relay is switched if an error (read/write) occurs during HDD access.
The relay is held until it is possible again to read or write.
The time for which the relay is held can also be set via the
Timer
.