DMS 80 / DMS 160 / DMS 240 / DMS 240 HSR
www.dallmeier.com
55
Fig. 6-29 :
Contact
recording mode
¾
Set the
Pre-Event time
(see above).
¾
Configure
Private Zones
if required (see section
Basic configuration
).
¾
Activate / configure the Timer if required (see section
Basic configuration
).
¾
Activate the
Use Database
option if required.
¾
Set the
Options
for contact recording.
¾
Set the
Contact Recording Duration
if required.
¾
Confirm with
OK
.
Normal Single
A contact triggers the recording of an individual picture.
Normal sequencer
The recording is triggered by the contact switching. It continues until the contact is released
again.
Start
The recording is triggered by the contact switching. The recording is stopped by an op-
posite contact function (
Stop recording (Contact recording mode)
or
Stop recording
camera (Contact recording mode)
).
Timer
The recording is started by the contact switching. Recording is stopped after the Contact
Recording Duration
expired.
Toggle
The recording is triggered by the contact switching. It is stopped again by the same contact
switching again.
Mark
A marker (index) will be saved to the track when the contact is triggered. While playing back
theses markings can be searched (
index search
and
extended search
).
The options
Event
and
Save
are not relevant in the
Contact
recording mode.