Timer
The recording is started by the contact switching. Recording is stopped After the
Contact
Recording Duration
expired.
Toggle
The recording is triggered by the contact switching. It is stopped again by the same contact
switching again.
Mark
A marker (index) will be saved to the track when the contact is triggered. While playing back
theses markings can be searched (
index search
and
extended search
).
6.4.1.4
Switching by motion
In the recording mode
Switching by motion
recording initially is done with
normal video
quality
. Thereby every image send by the camera will be analyzed. If a change of a certain
proportion of the picture content is detected between two consecutive images, an image
comparison event (event) has taken place. This picture comparison event triggers the swit-
ching to permanent recording with
high video quality
.
Recording with
high video quality
will be stopped when the
Switching Duration
is expi-
red and no further motion is detected.
¾
Ensure that the
Expert Mode
option is activated.
¾
Set the
Switching by motion
recording mode.
¾
Observe the explanations given below.
Fig. 6-23 : Switching by motion recording mode
¾
Configure
Private Zones
if required (see section
Basic configuration
).
¾
Activate / configure the
Camera Timer
if required (see section
Basic configuration
).
¾
Activate the
Use
Database
option if required (see above).
¾
Configure the
Active
Areas
if required (see section
Basic configuration
).
¾
Set the
Sensitivity
of the motion detection (see above).
¾
Set the
Switching Duration
.
¾
Set the
Motion Estimation
for the memory calculation (see above).
¾
Confirm with