SiEBE18-526
Troubleshooting
239
Part 8
Troubleshooting
1. Caution for Diagnosis..........................................................................241
1.1
Troubleshooting with the Operation Lamp (RA Indoor Unit) ................241
1.2
Troubleshooting with the LED on the SkyAir Indoor Unit .....................242
1.3
Troubleshooting with the LED on the Outdoor Unit..............................243
1.4
Troubleshooting with the LED on the BP Unit ......................................244
2. Service Check Function ......................................................................245
2.1
RA Indoor Unit Wireless Remote Controller.........................................245
2.2
SkyAir Indoor Unit INSPECTION/TEST Button....................................248
2.3
SkyAir Indoor Unit Wired Remote Controller........................................249
2.4
SkyAir Indoor Unit Wireless Remote Controller ...................................250
2.5
Sky Air Indoor Unit Error Codes and LED Indication............................252
2.6
Malfunction Code Indication by Outdoor Unit PCB ..............................253
3. List of Malfunction Code......................................................................255
4. Troubleshooting for RA Indoor Unit.....................................................257
4.1
Indoor Unit PCB Abnormality ...............................................................257
4.2
Freeze-up Protection Control or High Pressure Control.......................258
4.3
Fan Motor or Related Abnormality .......................................................260
4.4
Thermistor or Related Abnormality (Indoor Unit)..................................263
4.5
Shutter Drive Motor / Shutter Limit Switch Abnormality .......................264
4.6
Check ...................................................................................................265
5. Troubleshooting for SkyAir Indoor Unit ...............................................268
5.1
Indoor Unit PCB Abnormality ...............................................................268
5.2
Malfunction of Drain Water Level System (Float Type) ........................269
5.3
Malfunction of Drain System ................................................................271
5.4
Indoor Unit Fan Motor Lock..................................................................272
5.5
Malfunction of Indoor Unit Fan Motor ...................................................273
5.6
Swing Flap Motor Malfunction / Lock ...................................................275
5.7
Malfunction of Capacity Setting............................................................277
5.8
Malfunction of Heat Exchanger Thermistor (R2T)................................278
5.9
Malfunction of Heat Exchanger Thermistor (R3T)................................279
5.10 Malfunction of Suction Air Thermistor ..................................................280
5.11 Malfunction of Remote Controller Thermistor.......................................281
5.12 Transmission Error (between Indoor Unit and Remote Controller) ......282
5.13 Transmission Error (between Main and Sub Remote Controller).........283
5.14 Malfunction of Field Setting Switch ......................................................284
5.15 Check ...................................................................................................285
6. Troubleshooting for BP Unit ................................................................287
6.1
Malfunction of Electronic Expansion Valve ..........................................287
6.2
Faulty BP Unit PCB ..............................................................................288
6.3
Faulty BP Liquid or Gas Pipe Thermistor .............................................289
6.4
Transmission Error between Indoor Unit and BP Unit..........................290
6.5
Transmission Error between Outdoor Unit and BP Unit.......................292
6.6
Check ...................................................................................................293
7. Troubleshooting for Outdoor Unit........................................................294
7.1
Faulty Outdoor Unit PCB......................................................................294
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...