![Daikin Super Multi Plus D-Series Service Manual Download Page 221](http://html1.mh-extra.com/html/daikin/super-multi-plus-d-series/super-multi-plus-d-series_service-manual_2460573221.webp)
Instruction
SiEBE18-526
210
System Configuration
Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the
service shop if this is the case.
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
•
Press “MODE” button and select “FAN”operation.
•
Press “ON/OFF” button and start operation.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
•
When
a multi outdoor unit is connected, make sure the heating operation is not used at the other room
befure you use the fan operation.
NOTE
• Operation with dusty air filters lowers the cooling (heating) capacity and wastes energy.
Air
is also prevented from flowing smoothly through the unit creating a noise.
• Operation with dirty filters :
(1)
cannot deodorize the air. (2)
cannot clean the air.
(3) results in poor heating or cooling.
(4) may cause odour.
• The air purifying filter and Photocatalytic deodorizing filter cannot be reused, even if washed.
• In principle, there is no need to replace the photocatalytic deodorizing filter. Remove the dust
periodically with a vacuum cleaner. However, it is recommended to replace the filter in the
following cases.
(1)
The paper material is torn or broken during cleaning.
(2)
The
filter
has become extremely dirty after long use.
• To order air purifying filter or Photocatalytic deodorizing filter, contact to the service shop where
you bought the air conditioner.
• Dispose of old air filters as non-burnable waste and Photocatalytic deodorizing filters as
burnable waste.
Item
Photocatalytic deodorizing filter (with frame)
Photocatalytic deodorizing filter (without frame)
Air purifying filter (with frame)
Air purifying filter (without frame)
Part No.
KAZ917B41
KAZ917B42
KAF925B41
KAF925B42
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...