SiEBE18-526
Wiring Diagrams
Appendix
373
2.3.5 Ceiling Mounted Cassette Type
FFQ25/35/50/60B7V1B
T
O OUTDOOR UNIT
C1
A3P
A4P
S1L
X1M
X2M
Q1M
R1T
SS1
R3T
R2T
R1T
F1U
HAP
A1P
M1F
M1P
M1S
V1TR
T1R
KPR
TC
RC
WIRED REMOTE CONTROL
X2M
2
3
1
FLOAT SWITCH
THERMO SWITCH(M1F EMBEDDED)
SELECTOR SWITCH(MAIN/SUB)
PHASE CONTROL CIRCUIT
SIGNAL TRANSMISSION CIRCUIT
TRANSFORMER(220-240V/22V)
SIGNAL RECEIVER CIRCUIT
PRINTED CIRCUIT BOARD
MAGNETIC RELAY(M1P)
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
TERMINAL STRIP
TERMINAL STRIP
FUSE(F5A 250V)
MOTOR(SWING FLAP)
MOTOR(DRAIN PUMP)
MOTOR(INDOOR FAN)
CAPACITOR(M1F)
THERMISTOR(AIR)
THERMISTOR(AIR)
THERMISTOR(COIL-2)
THERMISTOR(COIL-1)
X2M
3
2
1
NOTE: 3
X24A
A1P
RECEIVER/DISPLAY UNIT
H05VV-U4G2.5
A3P
BS1
SS1
SS2
X40A
X60A
X61A
X33A
X35A
X2A
H1P
H2P
H3P
H4P
CONNECTOR FOR OPTIONAL PARTS
SS2
SS1
PUSH BUTTON(ON/OFF)
X1A
X2M
3
2
1
A4P
X1A
GRN/YLW
WHT
BLK
RED
H2P
H3P
H4P
H1P
BS1
F1U
X27A
X40A
X60A
X61A
RC
X19A
R1T
t°
TC
X18A
R2T
t°
X25A
KPR
X10A
X17A
R3T
YLW
YLW
WHT
t°
YLW
YLW
X33A
T1R
t°
M1P
~
M
X11A
X35A
HAP
V1TR
NOTE: 3
X24A
X1M
X36A
X15A
A1P
X20A
CONTROL BOX
X5A
BLK
RED
3D038357B
A1P
X1M
F2
P2
F1
P1
GRN
NOTE: 5
YL
W
C1
WHT
NE
X2M
S1L
T1R
SS1
P2
MSW
P1
M1S
M1F
C1
~
M
R1T
Q1M
IN CASE OF SIMULTANEOUS
OPERATION SYSTEM
INDOOR UNIT
(MASTER)
INDOOR UNIT
(SLAVE)
REMOTE
CONTROL
TO OUTDOOR
UNIT
WIRED
REMOTE
CONTROL
: CONNECTER DISCRIMINATION COLOUR FOR COMPONENTS.
: CONNECTER COLOUR FOR COMPONENTS.
: CONNECTER COLOUR FOR PRINTED CIRCUIT BOARD.
NOTES:
1.
: TERMINAL
:
FIELD WIRING,
: CONNECTOR
2. IN CASE USING CENTRAL REMOTE CONTROL, CONNECT IT TO THE UNIT IN
ACCORDANCE WITH THE ATTACHED INSTALLATION MANUAL.
3. X24A IS CONNECTED WHEN THE WIRELESS REMOTE CONTROL KIT IS
BEING USED.
4. REMOTE CONTROL MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM,
CONFIRM ENGINEERING MATERIALS AND CATALOGS, ETC. BEFORE CONNECTING.
5. GROUND THE SHIELD OF THE REMOTE CONTROL CORD TO THE INDOOR UNIT(IN CASE OF USING SHIELD WIRE).
6. SYMBOLS SHOW AS FOLLOWS: RED: RED BLK: BLACK WHT: WHITE YLW: YELLOW PRP: PURPLE GRY: GRAY BLU: BLUE
LIGHT EMITTING DIODE
(SERVICE MONITOR GREEN)
INFRARED REMOTE CONTROL
(RECEIVER/DISPLAY UNIT)
LIGHT EMITTING DIODE
(ON-RED)
LIGHT EMITTING DIODE
(TIMER-GREEN)
LIGHT EMITTING DIODE
(FILTER SIGN-RED)
LIGHT EMITTING DIODE
(DEFROST-ORANGE)
SELECTOR SWITCH
(MAIN/SUB)
SELECTOR SWITCH
(WIRELESS ADDRESS SET)
CONNECTOR
(ADAPTOR FOR WIRING)
CONNECTOR
(GROUP CONTROL ADAPTOR)
CONNECTOR
(ON/OFF INPUT FROM OUTSIDE)
CONNECTOR
(INTERFACE ADAPTOR
FOR SKYAIR SERIES)
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...