SiEBE18-526
Wiring Diagrams
Appendix
367
2. Wiring Diagrams
2.1
Outdoor Units
RMXS112/140/160D7V3B
L1R
A2P
A3P
U
V1T
N
P2
P1
P3
P4
W
V2R
V
E1
C2
X1M
Z1C
K1M
LB
LC
LA
M1C
U
U
L N
V
V
3~
MS
R1
Z1F
C3
C1
W
W
K2R
F1U
NB
R2
NC
NA
N
N
N=5
V1R
M1F
X1A
Z2C
WHT(RED MARKING)
3~
MS
PS
X206A
X60A
M2F
Z3C
3~
MS
S1PH
P <
X207A
HAP
X205A
X1A
A1P
X25A
1
Y1S
R3T
t
°
X2A
X1M
A
X34A
Y2S
K1R
C/H SELECTOR
X3A
B
K2R
1
R2T
t
°
C
Y3S
X5A
R4T
TO BP UNIT
F1
t
°
K4R
E1HC
F2
X6A
X37A
R5T
TO OUT/D UNIT
t
°
F1
HAP
X22A
BS1
K5R
H1P
F2
BS2
OFF
OFF
H2P
ON
ON
H3P
t
°
BS3
1
1
H4P
T1R
DS2
DS1
2
2
H5P
3
3
BS4
H6P
4
4
H7P
BS5
X23A
X28A
X26A
X45A
X46A
X44A
NOTE: 4
X24A
S1NPL
S1NPH
t
°
6
6
Y2E
R1T
Y1E
M
M
L
N
POWER SUPPLY
230V~50Hz
YLW
+
-
RED
RED
+
+
RED
+
+
WHT
GRN / YLW
BLU
BLU
BLU
-
-
BRN
RED
RED
RED
WHT
WHT
WHT
WHT
RED
BLU
BS~15
C1, 2, 3
A3P
A2P
K2R
HAP
HAP
K4R
K2R
K5R
DS1, 2
R2
M2F
E1HC
R3T
R5T
R4T
R2T
Y2S
Y2E
S2S
Y3S
F1U
H1P~7P
A1P
K1R
K1M
L1R
PS
V1T
R1
S1PH
S1NPL
V1R,V2R
M1C
M1F
R1T
T1R
Y1S
Y1E
S1S
Z1F
Z1C~3C
S1NPH
X1M
X1M
L-RED
C/H SELECTOR (KRC19-26A)
POWER MODULE(A2P)
CRANKCASE HEATER
SELECTOR SWITCH (FAN/COOL · HEAT)
SELECTOR SWITCH (COOL/HEAT)
SOLENOID VALVE(RECEIVER GAS PURGE)
REACTOR
MOTOR (COMPRESSOR)
MOTOR (FAN)
MOTOR (FAN)
PRESSURE SWITCH (HIGH)
PRESSURE SENSOR (LOW)
PILOT LAMP(SERVICE MONITOR-GREEN)(A2P)
PILOT LAMP(SERVICE MONITOR-GREEN)(A1P)
PRESSURE SENSOR (HIGH)
TRANSFORMER (230V/24V)
PRINTED CIRCUIT BOARD (NOISE FILTER)
ELECTRONIC EXPANSION VALVE (SUB COOL)
ELECTRONIC EXPANSION VALVE (MAIN)
FUSE( 6.3A/250V)
PRINTED CIRCUIT BOARD (MAIN)
PRINTED CIRCUIT BOARD (INV)
MAGNETIC CONTACTOR (M1C)
MAGNETIC RELAY (K1M)
DIP SWITCH
CAPACITOR
NOISE FILTER (WITH SURGE ABSORBER)
THERMISTOR (SUCTION)
IGBT (A2P)
NOISE FILTER (FERRITE CORE)
TERMINAL STRIP (CONTROL) (A1P)
TERMINAL STRIP (POWER SUPPLY)
SOLENOID VALVE (HOT GAS)
SOLENOID VALVE(4 WAY VALVE)
SWITCHING POWER SUPPLY
MAGNETIC RELAY (Y2S)
MAGNETIC RELAY (Y3S)
MAGNETIC RELAY (E1HC)
MAGNETIC RELAY (Y1S)
RESISTOR (CURRENT LIMITING)
RESISTOR (CURRENT SENSOR)
THERMISTOR (AIR)
THERMISTOR (M1C DISCHARGE)
THERMISTOR (HEAT EXC. DEICER)
THERMISTOR (HEAT EXC. OUTLET)
T
N-BLU
+
COOL
HEAT
S2S
FRONT
A1P
X1M
A3P
X1M
A
VIEW A
L1R
A2P
C/H SELECTOR (OPTIONAL ACCESSORY)
PUSH BUTTON SWITCH
(MODE, SET, RETURN, TEST, RESET)
PILOT LAMP(SERVICE MONITOR-ORANGE)
[H2P]PREPARE, TEST------------FLICKERING
MALFUNCTION DETECTION---LIGHT UP
THE POSITION OF
COMPRESSOR
TERMINAL
THE ENTRANCE
OF WIRE
NOTE: 8
BP UNIT
(F1)(F2)
S1S
FAN
COOL
HEAT
NOTES: 1. THIS WIRING DIAGRAM IS APPLIED ONLY TO THE OUTDOOR UNIT.
2. : FIELD WIRING.
3. : TERMINAL STRIP , : MOVABLE CONNECTOR : FIXED CONNECTOR : TERMINAL :
PROTECTIVE EARTH (SCREW) : NOISELESS EARTH
4. WHEN USING THE OPTION ADAPTOR, REFER TO THE INSTALLATION MANUAL.
5. REFER TO "OPERATION CAUTION LABEL" (ON BACK OF FRONT PLATE), HOW TO USE BS1~BS5 AND DS1 · 2SWITCH.
6. WHEN OPERATING, DON'T SHORT CIRCUIT FOR PROTECTION DEVICE. (S1PH)
7. COLORS BLU : BLUE BRN : BROWN GRN : GREEN RED : RED WHT : WHITE YLW : YELLOW.
8. REFER TO THE INSTALLATION MANUAL, FOR CONNECTION WIRING TO BP UNIT-OUTDOOR TRANSMISSION F1 · F2.
3D048790
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...