SiEBE18-526
Instruction
System Configuration
167
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
1, 3
2
To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button” to
set the clock to the present time.
3. Press “CLOCK button”.
blinks.
Holding down “
”
or “
” button rapidly
increases or decreases the time display.
Turn the breaker ON
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
NOTE
Tips for saving energy
•
Be
careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
•
Cover
windows with a blind or a curtain.
Blocking
sunlight and air from outdoors increases the cooling (heating) effect.
•
Clogged
air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
Please note
•
The
air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If
you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
•
Use the air conditioner in the following conditions.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
Recommended temperature setting
For cooling: 26°C – 28°C
For heating: 20°C – 24°C
Mode
COOL
HEAT
DRY
Operating conditions
If operation is continued out of this range
Outdoor temperature:
2MK(X)S
10 to 46 °C
3/4MK(X)S
–10 to 46 °C
RK(X)S
–10 to 46 °C
RK(X)H
10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
Outdoor temperature:
2MXS
–10 to 21 °C
3/4MXS
–15 to 21 °C
RXS
–15 to 21 °C
RXH
–10 to 21 °C
Indoor temperature: 10 to 30 °C
Outdoor temperature:
2MK(X)S
10 to 46 °C
3/4MK(X)S
–10 to 46 °C
RK(X)S
–10 to 46 °C
RK(X)H
10 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
(In
multi system, it may work to stop the operation of the
outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
• A safety device may work to stop the operation.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...