5. NAME AND FUNCTION OF
EACH SWITCH AND
DISPLAY ON THE REMOTE
CONTROL
Refer to figure 1 on page
[1]
1
2
3
4
5
6
7
8
9
10
ON/OFF BUTTON
Press the button and the system will start.
Press the button again and the system will
stop.
OPERATION LAMP (RED)
The lamp lights up during operation.
DISPLAY “
” (UNDER CENTRAL-
IZED CONTROL)
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
DISPLAY “
” “
” “
” “
”
(VENTILATION/AIR CLEANING)
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional accessories).
DISPLAY “
” “
” “
” “
” “
”
(OPERATION MODE)
This display shows the current OPERATION
MODE. For cooling only type, “
” (Auto)
and “
” (Heating) are not installed.
DISPLAY “
TEST
” (INSPECTION/TEST
OPERATION)
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
DISPLAY “
” (PROGRAMMED TIME)
This display shows the PROGRAMMED
TIME of the system start or stop.
DISPLAY “
” (SET TEMPERATURE)
This display shows the set temperature.
DISPLAY “
” (FAN SPEED)
This display shows the set fan speed.
DISPLAY “
” (AIR FLOW FLAP)
Refer to “AIR FLOW DIRECTION ADJUST”.
11
12
13
14
15
16
17
18
19
20
21
22
DISPLAY “
” (TIME TO CLEAN AIR
FILTER)
Refer to “HOW TO CLEAN THE AIR FILTER”.
DISPLAY “
” (DEFROST)
Refer to “DEFROST OPERATION".
NON-FUNCTIONING DISPLAY
If that particular function is not available,
pressing the button may display the words
“NOT AVAILABLE” for a few seconds.
When running multiple units simultaneously
The “NOT AVAILABLE” message will only be
appear if none of the indoor units is equipped
with the function. If even one unit is equipped
with the function, the display will not appear.
TIMER MODE START/STOP BUTTON
Refer to “PROGRAM TIMER OPERATION”.
TIMER ON/ OFF BUTTON
Refer to “PROGRAM TIMER OPERATION”.
INSPECTION/TEST OPERATION
BUTTON
This button is used only by qualified service
persons for maintenance purposes.
PROGRAMMING TIME BUTTON
Use this button for programming “START and/
or STOP” time.
TEMPERATURE SETTING BUTTON
Use this button for SETTING TEMPERA-
TURE.
FILTER SIGN RESET BUTTON
Refer to “HOW TO CLEAN THE AIR FILTER”.
FAN SPEED CONTROL BUTTON
Press this button to select the fan speed,
HIGH or LOW, of your choice.
OPERATION MODE SELECTOR BUTTON
Press this button to select OPERATION MODE.
AIR FLOW DIRECTION ADJUST BUTTON
Refer to “AIR FLOW DIRECTION ADJUST”.
NOTE
• For the sake of explanation, all indications are
shown on the display in figure 1 contrary to
actual running situations.
• Operating procedure varies with heat pump type
and cooling only type. Contact your Daikin dealer
to confirm your system type.
• To protect the unit, turn on the main power switch
6 hours before operation.
Refer to figure 1 on page
[1]
6. OPERATION PROCEDURE
Summary of Contents for Super Multi Plus D-Series
Page 1: ...SiEBE18 526 D Series Service Manual Applied Models zSuper Multi Plus Heat Pump...
Page 12: ...SiEBE18 526 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 63: ...Refrigerant Flow for Each Operation Mode SiEBE18 526 52 Refrigerant Circuit...
Page 249: ...Instruction SiEBE18 526 238 System Configuration...