Si12-308
Specifications
Specifications
57
60Hz 220V
Notes:
1. The data are based on the conditions shown in the table below.
2. The values under the test conditions prescribed in CNS are as follows.
Cooling
Heating
Model
3MXD68BVMT
4MXD80BVMT
Cooling
Heating
Cooling
Heating
Cooling Capacity
kW
—
—
Power Consumption
W
—
—
Running Current
A
—
—
Casing Color
Ivory White
Pale Ivory
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC45ZXD
2YC45ZXD
Motor Output
W
1,380
1,380
Refrigerant Oil
Model
SUNISO 4GSD.I.
SUNISO 4GSD.I.
Charge
L
0.75
0.75
Refrigerant
Type
R22
R22
Charge
kg
2.6
3.1
Air Flow Rates
m³/min
H
51
47.6
48.5
45
L
45
45
42
42
cfm
H
1,472
1,374
1,400
1,299
L
1,299
1,299
1,212
1,212
Fan
Type
Propeller
Propeller
Motor Output
W
53
51
Running Current
A
H: 0.33 / L: 0.25
H: 0.44 / L: 0.34
Power Consumption
W
H: 68 / L: 46
H: 60 / L: 41
Starting Current
A
11.0
15.4
Dimensions (H×W×D)
mm
735×936×300
908×900×320
Packaged Dimension
mm
960×357×784
926×394×942
Weight
kg
59
73
Gross Weight
kg
63
80
Operation Sound
dBA
48
49
48
49
Piping Connection
Liquid
mm
φ
6.4×3
φ
6.4×3,
φ
9.5×1
Gas
mm
φ
12.7×2,
φ
15.9×1
φ
9.5×1,
φ
12.7×1,
φ
15.9×2
Drain
mm
φ
16.0
φ
25.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
45 (for Total of Each Room)
70 (for Total of Each Room)
m
25 (for One Room)
25 (for One Room)
Amount of Additional Charge
g/m
20 (30m or more)
20 (40m or more)
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
15 (between Indoor Unit and Outdoor Unit)
m
7.5 (between Indoor Units)
7.5 (between Indoor Units)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 21°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Outdoor Unit
Indoor Unit
Cooling
Capacity
(kcal/h)
Power
Consumption
(W)
Running
Current
(A)
EER
(kcal/h×W)
3MXD68B
25+35+50
5,850
2,340
10.7
2.50
4MXD80B
25+25+35+50
6,880
3,350
15.4
2.05
Outdoor Unit
Indoor Unit
Cooling
Capacity
(kcal/h)
Power
Consumption
(W)
Running
Current
(A)
EER
(kcal/h×W)
3MXD68B
25+35+50
7,395
2,400
11.0
3.08
4MXD80B
25+25+35+50
8,255
2,400
11.0
3.44
Summary of Contents for Super Multi NX B series
Page 7: ...Si12 308 vi Table of Contents ...
Page 29: ...List of Functions Si12 308 18 List of Functions ...
Page 71: ...Specifications Si12 308 60 Specifications ...
Page 175: ...Instruction Si12 308 164 System Configuration ...
Page 227: ...Check Si12 308 216 Service Diagnosis ...
Page 288: ...Si12 308 Wiring Diagrams Appendix 277 FTXD50BVMC FTXD60 71BVMC ...
Page 299: ...Si12 308 iv Index ...