![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-b-series/super-multi-nx-b-series_service-manual_2459105065.webp)
Specifications
Si12-308
54
Specifications
Floor Standing Type
230V, 50Hz
Model
FVXS25BVMB
FVXS35BVMB
Cooling
Heating
Cooling
Heating
Rated Capacity
2.5kW Class
3.5kW Class
Front Panel Color
Almond White
Almond White
Air Flow Rates
m³/min
(cfm)
H
8.1 (286)
9.2 (325)
8.3 (293)
9.2 (325)
M
6.2 (219)
7.0 (247)
6.3 (222)
7.1 (251)
L
4.3 (152)
4.8 (169)
4.3 (152)
5.0 (177)
SL
3.4 (120)
3.5 (124)
3.4 (120)
3.6 (127)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
14 + 14
14 + 14
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Upward
Right, Left, Horizontal and Upward
Air Filter
Removal-Washable-Mildew Proof
Removal-Washable-Mildew Proof
Running Current (Rated)
A
0.14
0.14
0.14
0.14
Power Consumption (Rated)
W
32
32
32
32
Power Factor
%
99.4
99.4
99.4
99.4
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
600×650×195
600×650×195
Packaged Dimension
mm
770×294×714
770×294×714
Weight
kg
13
13
Gross Weight
kg
19
19
Operation
Sound
H/M/L/SL
dBA
38/32/26/23
38/32/26/23
39/33/27/24
39/34/29/26
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
20.0
φ
20.0
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Model
FVXS50BVMB
Cooling
Heating
Rated Capacity
5.0kW Class
Front Panel Color
Almond White
Air Flow Rates
m³/min
(cfm)
H
10.8 (381)
13.2 (466)
M
9.2 (325)
11.3 (399)
L
7.7 (272)
9.4 (332)
SL
6.7 (237)
8.3 (293)
Fan
Type
Cross Flow Fan
Motor Output
W
14 + 14
Speed
Steps
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Upward
Air Filter
Removal-Washable-Mildew Proof
Running Current (Rated)
A
0.25
0.31
Power Consumption (Rated)
W
55
70
Power Factor
%
91.7
94.1
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
600×650×195
Packaged Dimension
mm
770×294×714
Weight
kg
13
Gross Weight
kg
19
Operation
Sound
H/M/L/SL
dBA
44/40/36/33
45/40/36/33
Heat Insulation
Both Liquid and Gas Pipes
Piping Connection
Liquid
mm
φ
6.4
Gas
mm
φ
12.7
Drain
mm
φ
20.0
Summary of Contents for Super Multi NX B series
Page 7: ...Si12 308 vi Table of Contents ...
Page 29: ...List of Functions Si12 308 18 List of Functions ...
Page 71: ...Specifications Si12 308 60 Specifications ...
Page 175: ...Instruction Si12 308 164 System Configuration ...
Page 227: ...Check Si12 308 216 Service Diagnosis ...
Page 288: ...Si12 308 Wiring Diagrams Appendix 277 FTXD50BVMC FTXD60 71BVMC ...
Page 299: ...Si12 308 iv Index ...