![background image](http://html1.mh-extra.com/html/daikin/super-multi-nx-b-series/super-multi-nx-b-series_service-manual_2459105080.webp)
Si12-308
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
69
1.4
Duct Connected Type
Connectors
Note:
Other designations
Control PCB
Detail (PCB 1)
Refer to PCB (1) Control on P64.
Display PCB
Detail (PCB 2)
1)
S1
(on PCB 1) Connector for fan motor
2) S1 (on PCB 2) Connector for control PCB
3)
S7
Connector for fan motor
4)
S21
Connector for
centralized control
to 5 rooms
5)
S26
Connector for display PCB
6)
S32
Connector for room temp / Heat exchanger thermistor
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 259 for more detail.
3)
SW1
OPERATION SWITCH
4)
LED1
(GRN) LED for operation
5)
LED2
(YLW) LED for timer
6)
LED3
(RED) LED for intelligent eye
Summary of Contents for Super Multi NX B series