List of Functions
Si12-308
10
List of Functions
1.2
Heat Pump Models
Category
Functions
F
T
XE25
/35
BVM
C
F
T
XD50
-71BVM
C
CDX2
5
-60
A
(B)VM
C
Category
Functions
F
T
XE25
/35
BVM
C
F
T
XD50
-71BVM
C
CDX2
5
-60
A
(B)VM
C
Basic
Function
Inverter
(with Inverter Power Control)
{
{ {
Health &
Clean
Air Purifying Filter with
Bacteriostatic & Virustatic
Functions
{
— —
Operation Limit for Cooling (°CDB)
—
— —
Photocatalytic Deodorizing Filter
{
— —
Operation Limit for Heating
(°CWB)
—
— —
Air Purifying Filter with
Photocatalytic Deodorizing
Function
—
{
—
PAM Control
—
— —
Longlife Filter
— — —
Compressor Oval Scroll Compressor
—
— —
Ultra-Longlife Filter (Option)
— — —
Swing Compressor
—
— —
Mould Proof Air Filter
{ {
—
Rotary Compressor
—
— —
Wipe-clean Flat Panel
{ {
—
Reluctance DC Motor
—
— —
Washable Grille
— — —
Comfortable
Airflow
Power-Airflow Flap
—
— —
Filter Cleaning Indicator
— — —
Power-Airflow Dual Flaps
{
{
—
Good-Sleep Cooling Operation
— — —
Power-Airflow Diffuser
—
— — Timer
24-Hour On/Off Timer
{ { {
Wide-Angle Louvers
{
{
—
Night Set Mode
{ { {
Vertical Auto-Swing
(Up and Down)
{
{
—
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{ { {
Horizontal Auto-Swing
(Right and Left)
—
{
—
Self-Diagnosis (Digital, LED)
Display
{
★
{
★
{
★
3-D Airflow
—
{
—
Wiring-Error Check
— — —
3-Step Airflow (H/P Only)
—
— —
Anticorrosion Treatment of
Outdoor Heat Exchanger
— — —
Comfort
Control
Auto Fan Speed
{
{ {
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
— — —
Indoor Unit Silent Operation
{
{ {
Flexible Voltage Correspondence
{ {
—
Night Quiet Mode (Automatic)
—
— —
High Ceiling Application
— — —
Outdoor Unit Silent Operation
(Manual)
—
— —
Chargeless
— — —
Intelligent Eye
{
{
—
Power-Selection
— — —
Quick Warming Function
—
— —
Remote
Control
5-Rooms Centralized Controller
(Option)
{ { {
Hot-Start Function
{
{ {
Remote Control Adaptor
(Normal Open-Pulse Contact)
(Option)
{ { {
Automatic Defrosting
—
— —
Remote Control Adaptor
(Normal Open Contact)(Option)
{ { {
Operation
Automatic Operation
{
{ {
Dlll-NET Compatible
(Adaptor)(Option)
{ { {
Programme Dry Function
{
{ {
Remote
Controller
Wireless
{ { {
Fan Only
{
{ {
Wired
— — —
Lifestyle
Convenience
New Powerful Operation
(Non-Inverter)
—
— —
Inverter Powerful Operation
{
{ {
Priority-Room Setting
—
— —
Cooling / Heating Mode Lock
—
— —
Home Leave Operation
{
{ {
Indoor Unit On/Off Switch
{
{ {
Signal Reception Indicator
{
{ {
Temperature Display
—
— —
Another Room Operation
—
— —
Note:
{
: Holding Functions
— : No Functions
★
: Digital Only
Summary of Contents for Super Multi NX B series
Page 7: ...Si12 308 vi Table of Contents ...
Page 29: ...List of Functions Si12 308 18 List of Functions ...
Page 71: ...Specifications Si12 308 60 Specifications ...
Page 175: ...Instruction Si12 308 164 System Configuration ...
Page 227: ...Check Si12 308 216 Service Diagnosis ...
Page 288: ...Si12 308 Wiring Diagrams Appendix 277 FTXD50BVMC FTXD60 71BVMC ...