![background image](http://html1.mh-extra.com/html/daikin/split-sensira-r32/split-sensira-r32_service-manual_4171547061.webp)
3
|
Components
Service manual
61
(A)(F)TXF20~71A + FTXF20~25B + (A)(F)TXF20~42C + (A)(F)TXF20~42D +
(A)(F)TXF20~42E + (A)RXF20~71A + RXF20~60B + (A)RXF20~42C +
(A)RXF20~42D + (A)RXF20~42E
Split Sensira R32
ESIE18-12G – 2023.01
8
Wrap a wet rag around the components near the compressor pipes. Heat the
brazing points of the compressor pipes using an oxygen acetylene torch and
remove the refrigerant pipes from the compressor pipes using pliers.
a
a
a
Compressor pipe
9
Stop the nitrogen supply when the piping has cooled down.
INFORMATION
It is ALSO possible to cut the component pipe(s) using a pipe cutter. Make sure to
remove the remaining component pipe end(s) from the refrigerant pipes by heating
the brazing point(s) of the component pipe(s) using an oxygen acetylene torch.
10
Remove the nuts and bolts and remove the compressor from the unit.
a
a
b
c
c
c
a
a
Nut
b
Compressor
c
Damper
11
Remove the 3 dampers from the compressor.
INFORMATION
The compressor dampers may look different.
12
Remove the bushings and keep them for re-use.
13
Install plugs or caps on the open pipe ends of the refrigerant piping to avoid
dirt or impurities from entering the piping.