![background image](http://html1.mh-extra.com/html/daikin/split-sensira-r32/split-sensira-r32_service-manual_4171547083.webp)
3
|
Components
Service manual
83
(A)(F)TXF20~71A + FTXF20~25B + (A)(F)TXF20~42C + (A)(F)TXF20~42D +
(A)(F)TXF20~42E + (A)RXF20~71A + RXF20~60B + (A)RXF20~42C +
(A)RXF20~42D + (A)RXF20~42E
Split Sensira R32
ESIE18-12G – 2023.01
a
a
Indoor unit fan motor cover
3
Remove the rubber from the indoor unit.
4
Remove the indoor unit fan motor from the indoor unit.
5
To install the indoor unit fan motor, see
82].
To install the DC fan motor assembly
1
Install the indoor unit fan motor in its correct location on the fan.
2
Install the rubber in front of the fan motor.
3
Click the indoor unit fan motor cover on the indoor unit. If removed, install
and tighten the screw on the right hand side of the fan motor cover.
a
a
Indoor unit fan motor cover
4
Install the switch box, see
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.