![background image](http://html1.mh-extra.com/html/daikin/split-sensira-r32/split-sensira-r32_service-manual_4171547073.webp)
3
|
Components
Service manual
73
(A)(F)TXF20~71A + FTXF20~25B + (A)(F)TXF20~42C + (A)(F)TXF20~42D +
(A)(F)TXF20~42E + (A)RXF20~71A + RXF20~60B + (A)RXF20~42C +
(A)RXF20~42D + (A)RXF20~42E
Split Sensira R32
ESIE18-12G – 2023.01
a
b
a
Expansion valve coil
b
Expansion valve coil harness
INFORMATION
The expansion valve and coil can have a different configuration / layout.
4
Cut all tie straps that fix the expansion valve coil harness.
5
Disconnect the expansion valve coil connector from the main PCB.
6
To install the expansion valve coil, see
To remove the expansion valve body
Prerequisite:
Recuperate the refrigerant from the refrigerant circuit, see
Prerequisite:
If needed, remove any parts or insulation to create more space for
the removal.
1
Remove the expansion valve coil, see
2
Remove the putty. Keep for re-use.
a
b
c
a
Putty
b
Expansion valve pipe
c
Expansion valve body