Troubleshooting by Error Code
Part 6 Service Diagnosis
182
Note(s)
Troubleshooting
RZF30/36AVMK
1. Blinking pattern: 0.2 seconds ON, 0.2 seconds OFF (blinking approximately 25 times in 10
seconds)
(Normally 0.4 seconds ON, 0.4 seconds OFF (blinking approximately 12 times in 10 seconds))
2. Optional accessories refer to adaptor for wiring, and other accessories.
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Is the power
supply voltage within the
normal range?
Correct the power supply
voltage.
NO
Is the
connector for the
indoor/outdoor relay
wiring to the terminal block
detached or loose?
Connect the indoor/outdoor
relay lines correctly.
YES
The HAP on
the outdoor unit main
PCB blinks rapidly (
∗
1)
continuously for more
than 1 minute.
Connect the indoor/outdoor
relay lines correctly.
(Indoor/outdoor relay line
phases do not match)
YES
Is there a
wrong wiring,
disconnection, loose terminal
or contact failure in the transmission
wiring between the indoor
and outdoor
units?
Is any
optional accessory (
∗
2)
connected?
Is the
power for the
optional accessory supplied
from between 1 and 2 on
terminal block
X2M?
Wire correctly and securely
fasten the terminal screws.
YES
Wire correctly.
NO
Is HAP on the
outdoor unit main PCB
blinking?
YES
YES
NO
NO
YES
YES
NO
NO
NO
A
B Go to the next page
Go to the next page