Si04-306
Specifications
Specifications
23
220-230-240V, 50Hz / 220-230V, 60Hz
Notes:
MAX. interunit piping length: 30m
MAX. interunit height difference: 20m
Amount of additional charge for piping length exceeding 10m : 20g/m(50/60class), 50g/m(71class)
The data are based on the conditions shown in the table below.
Model
Indoor Units
FTXD71BVMA
Outdoor Units
RXD71BVMA
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
7.1 (0.9~8.0)
8.5 (0.9~9.7)
Btu/h
24,240 (3,070~27,310)
29,020 (3,070~33,120)
kcal/h
6,110 (770~6,880)
7,310 (770~8,340)
Moisture Removal
L/h
4.5
—
Running Current (Rated)
A
11.9-11.4-10.9/11.9-11.4
11.8-11.3-10.9/11.8-11.3
Power Consumption
Rated (Min.~Max.)
W
2,600 (450~3,350)
2,580 (450~3,490)
Power Factor
%
99.3-99.2-99.4/99.3-99.2
99.4-99.3-98.6/99.4-99.3
COP
W/W
2.73
3.29
Piping
Connections
Liquid
mm
φ
9.5
Gas
mm
φ
15.9
Drain
mm
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Indoor Unit
FTXD71BVMA
Front Panel Color
White
Air Flow Rate
m³/min
(cfm)
H
18.3 (646)
19.8 (699)
M
15.3 (540)
17.1 (604)
L
12.7 (448)
14.4 (508)
SL
11.3 (399)
12.6 (445)
Fan
Type
Cross Flow Fan
Motor Output
W
43
Speed
Steps
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Air Filter
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.23-0.22-0.21/0.23-0.22
0.23-0.22-0.21/0.23-0.22
Power Consumption (Rated)
W
50
50
Power Factor
%
98.8-98.8-99.2/98.8-98.8
98.8-98.8-99.2/98.8-98.8
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
Weight
kg
12
Gross Weight
kg
17
Operation
Sound
H/M/L/SL
dBA
46/42/37/34
46/42/37/34
Sound Power H
dBA
63
63
Outdoor Unit
RXD71BVMA
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC63ZXD
Motor Output
W
1,900
Refrigerant
Oil
Model
SUNISO 4GSD.I.
Charge
L
0.75
Refrigerant
Model
R22
Charge
kg
1.80
Air Flow Rate
(H/L)
m³/min
51.5/41.5
41.9/37.4
cfm
1,818/1,465
1,479/1,320
Fan
Type
Propeller
Motor Output
W
53
Running Current (Rated)
A
11.67-11.18-10.69/11.67-11.18
11.57-11.08-10.69/11.57-11.08
Power Consumption (Rated)
W
2,550
2,530
Power Factor
%
99.3-99.2-99.4/99.3-99.2
99.4-99.3-98.6/99.4-99.3
Starting Current
A
11.3
Dimensions (H×W×D)
mm
735×825×300
Packaged Dimensions (H×W×D)
mm
784×960×390
Weight
kg
57
Gross Weight
kg
61
Operation
Sound
H/L
dBA
52/49
52/49
Sound Power H
dBA
66
66
Drawing No.
3D040792
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
Summary of Contents for FTKD50BVM
Page 17: ...List of Functions Si04 306 8 List of Functions ...
Page 35: ...Specifications Si04 306 26 Specifications ...
Page 143: ...Check Si04 306 134 Service Diagnosis ...
Page 187: ...Outdoor Unit Si04 306 178 Removal Procedure ...
Page 191: ...Others Si04 306 182 Others ...
Page 201: ...Wiring Diagrams Si04 306 192 Appendix FTKD 18 24 28 BVMS ...
Page 203: ...Wiring Diagrams Si04 306 194 Appendix RKD 18 24 28 BVMS ...