Specifications
Si04-306
10
Specifications
1.
Specifications
1.1
Cooling Only - R410A Series
240V, 50Hz
Notes:
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Model
Indoor Units
FTKS50BVMA
FTKS60BVMA
FTKS71BVMA
Outdoor Units
RKS50BVMA
RKS60BVMA
RKS71BVMA
Capacity
Rated (Min.~Max.)
kW
5.0 (0.9~5.8)
6.0 (0.9~6.7)
7.1 (0.9~8.0)
Btu/h
17,070 (3,070~19,800)
20,480 (3,070~22,870)
24,240 (3,070~27,310)
kcal/h
4,300 (770~4,990)
5,160 (770~5,760)
6,110 (770~6,880)
Moisture Removal
L/h
2.9
3.9
4.5
Running Current (Rated)
A
7.0
8.9
10.6
Power Consumption
Rated (Min.~Max.)
W
1,660 (450~2,300)
2,120 (450~2,450)
2,530 (450~3,070)
Power Factor
%
98.8
99.3
99.4
COP
W/W
3.01
2.83
2.81
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
φ
15.9
Drain
mm
φ
18.0
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Unit
FTKS50BVMA
FTKS60BVMA
FTKS71BVMA
Front Panel Color
White
White
White
Air Flow Rate
m³/min
(cfm)
H
11.4 (402)
16.2 (572)
16.8 (593)
M
9.8 (346)
13.9 (491)
14.2 (501)
L
8.7 (307)
11.9 (420)
11.9 (420)
SL
7.7 (272)
10.7 (378)
11.2 (395)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Motor Output
W
40
43
43
Speed
Steps
5 Steps, Silent and Auto
5 Steps, Silent and Auto
5 Steps, Silent and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable/Washable/Mildew Proof
Removable/Washable/Mildew Proof
Removable/Washable/Mildew Proof
Running Current (Rated)
A
0.17
0.19
0.21
Power Consumption (Rated)
W
40
45
50
Power Factor
%
98.0
98.7
99.2
Temperature Control
Microcomputer Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×795×238
290×1,050×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
280×840×338
337×1,147×366
337×1,147×366
Weight
kg
9
12
12
Gross Weight
kg
13
17
17
Operation
Sound
H/M/L/SL
dBA
44/40/35/32
45/41/36/33
46/42/37/34
Sound Power
H
dBA
63
63
63
Outdoor Unit
RKS50BVMA
RKS60BVMA
RKS71BVMA
Casing Color
Ivory White
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC32HXD
2YC32HXD
2YC45BXD
Motor Output
W
1,500
1,500
1,900
Refrigerant Oil
Type
FVC50K
FVC50K
FVC50K
Charge
L
0.65
0.65
0.75
Refrigerant
Type
R410A
R410A
R410A
Charge
kg
1.20
1.70
1.70
Air Flow Rate
m³/min (cfm)
H
47.7(1,684)
47.6 (1,680)
51.5 (1,818)
L
44.1(1,557)
44.1 (1,557)
41.5 (1,465)
Fan
Type
Propeller
Propeller
Propeller
Motor Output
W
53
53
53
Running Current (Rated)
A
6.83
8.71
10.39
Power Consumption (Rated)
W
1,620
2,075
2,480
Power Factor
%
98.8
99.3
99.5
Starting Current
A
7
8.9
10.6
Dimensions (H×W×D)
mm
735×825×300
735×825×300
735×825×300
Packaged Dimensions (H×W×D)
mm
784×960×390
784×960×390
784×960×390
Weight
kg
48
52
54
Gross Weight
kg
53
57
59
Operation
Sound
H/L
dBA
47/44
49/46
52/49
Sound Power
H
dBA
63
64
66
Drawing No.
3D040801
3D040802
3D040803
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m
Summary of Contents for FTKD50BVM
Page 17: ...List of Functions Si04 306 8 List of Functions ...
Page 35: ...Specifications Si04 306 26 Specifications ...
Page 143: ...Check Si04 306 134 Service Diagnosis ...
Page 187: ...Outdoor Unit Si04 306 178 Removal Procedure ...
Page 191: ...Others Si04 306 182 Others ...
Page 201: ...Wiring Diagrams Si04 306 192 Appendix FTKD 18 24 28 BVMS ...
Page 203: ...Wiring Diagrams Si04 306 194 Appendix RKD 18 24 28 BVMS ...