Si04-306
Outdoor Unit
Removal Procedure
165
5
Loosen the screw of the
control PCB.
6
Undo the two claws and
release the control PCB
from the ditch of the
front side.
7
Disconnect the
harnesses while
opening the control
PCB.
S10
: to the terminal
strip
AC2
: to the terminal
strip
8
Disconnect the
connectors.
S51
: to the service
monitor PCB
S101
: to the service
monitor PCB
Step
Procedure
Points
Summary of Contents for FTKD50BVM