Si04-306
Troubleshooting
Service Diagnosis
93
4.
Troubleshooting
4.1
Error Codes and Description
★
: Displayed only when system-down occurs.
Code Indication Description
Reference
Page
System
00
Normal
—
U0
★
Insufficient gas
120
U2
Low-voltage detection
122
U4
Signal transmission error (between indoor and outdoor units)
100
Indoor
Unit
A1
Indoor unit PCB abnormality
94
A5
Freeze-up protection control or high pressure control
95
A6
Fan motor or related abnormality
97
C4
Heat exchanger thermistor abnormality
99
C9
Room temperature thermistor abnormality
99
Outdoor
Unit
E5
★
OL activation (compressor overload)
101
E6
★
Compressor lock
102
E7
DC fan lock
103
E8
Input over current detection
104
EA
Four way valve abnormality
106
F3
Discharge pipe temperature control
108
F6
High pressure control in cooling
123
H6
Position sensor abnormality
109
H8
CT or related abnormality
110
H9
Outdoor air thermistor or related abnormality
112
J3
Discharge pipe thermistor or related abnormality
112
J6
Heat exchanger thermistor or related abnormality
112
L3
Electrical box temperature rise
114
L4
Radiation fin temperature rise
116
L5
Output over current detection
118
P4
Radiation fin thermistor or related abnormality
112
Summary of Contents for FTKD50BVM
Page 17: ...List of Functions Si04 306 8 List of Functions ...
Page 35: ...Specifications Si04 306 26 Specifications ...
Page 143: ...Check Si04 306 134 Service Diagnosis ...
Page 187: ...Outdoor Unit Si04 306 178 Removal Procedure ...
Page 191: ...Others Si04 306 182 Others ...
Page 201: ...Wiring Diagrams Si04 306 192 Appendix FTKD 18 24 28 BVMS ...
Page 203: ...Wiring Diagrams Si04 306 194 Appendix RKD 18 24 28 BVMS ...