Si04-306
Indoor Unit
Removal Procedure
141
1.3
Removal of the Horizontal
Blades
/ Vertical Blades
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the
horizontal
blade
s.
1
Open the horizontal
blades.
It has no fixing screws inside
blades, though previous
models had.
2
Undo the left pivot of
the horizontal blades.
3
Bend the horizontal
blades slightly and
release the center
pivots.
Slide the horizontal
blades to the left and
release the right pivot.
Installation procedure
1. Since key pattern hook is
provided, rotate the blades
and fit it to the right pivot
first.
2. Fit the blades to the center
and left pivots.