7
Parameter settings
Operating Instructions
31
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
7.3.5
Menu: 1x Hot water
[→ Main menu → User → 1x load]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
1x Hot Water
Off
Start of one-time domestic hot water preparation to the set target value
[Hot water temp. setpoint 1] without time limit, independent of the heating
programs.
-
E
E
On
Tab. 7-10
Parameter in menu: "1x hot water"
7.4
Time Program
[→ Main menu → Time program]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Party
0 – 360 min
This operating mode can be used to set a unique time for temporarily ex-
tending the heating time of the internal heating circuit.
0 min
15 min
E
E
Away
0 – 360 min
This operating mode can be used to set a one-off time for temporary regu-
lation to the parametrised absence temperature.
0 min
15 min
E
E
Vacation
Date 1st day
-
Date last day
The internal heating circuit provides continuous (24 h per day) regulation to
the parametrised absence temperature ([Room temperature reduced] para-
meter).
A calendar function can be used to enter a time period of absence.
-
1 day
E
E
Holiday
Date 1st day
-
Date last day
A calendar function can be used to enter a time period of presence.
During this period of time, regulation is carried out exclusively according to
the settings for "Sunday" in the [Heating circuit auto. 1] and [Hot water
auto. 1] time programs.
-
1 day
E
E
Heating circuit
automatic 1
In this menu, the 1st time program can be parametrised for the internal HC.
3 switching cycles with a resolution of 15 minutes can be set. A separate
entry for each weekday is possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
15 min
E
E
Heating circuit
automatic 2
In this menu, the 2nd time program for the internal HC can be paramet-
rised. 3 switching cycles with a resolution of 15 minutes can be set. A sep-
arate entry for each weekday is possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
15 min
E
E
Hot water
automatic 1
This menu can be used to parametrise the 1st time program for domestic
hot water preparation. 3 switching cycles with a resolution of 15 minutes
can be set. A separate entry for each weekday is possible. Format: (on)
hh:mm - hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
15 min
E
E
Hot water
automatic 2
This menu can be used to parametrise the 2nd time program for domestic
hot water preparation. 3 switching cycles with a resolution of 15 minutes
can be set. A separate entry for each weekday is possible. Format: (on)
hh:mm - hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
15 min
E
E
Circulation
program
This menu can be used to parametrise a timer program for the circulation
pump. 3 switching cycles with a resolution of 15 minutes can be set. A sep-
arate entry for each weekday is possible. Format: (on) hh:mm - hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
15 min
E
E