7
Parameter settings
Operating Instructions
46
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE
HF
BPV
-
Current position of 3UVB1 mixing valve (0%: heating network; 100%: in-
ternal bypass)
-
-
S
S
3UVD
-
Current position of the 3UVDHW mixing valve (0% heating network; 100%
hot water storage tank)
-
-
S
S
Temperat-
ureA2
-
Current outside temperature in °C (on optional outside temperature
sensor)
-
-
S
S
Tliq2
-
Current refrigerant temperature °C
-
-
S
S
Quiet mode
Inactive
Status of the Quiet mode
-
-
S
S
Active
Active at night
Heating sup-
port
Off
Status of the heating support
-
-
S
S
On
Tab. 7-27
Parameter in menu: "Overview"
7.7.2
Values
[→ Main menu → Information → Values]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Feed temper-
ature current
0 – 100 °C
The current feed temperature of the heat generator (t
V1
) is displayed in °C.
-
1 °C
S
S
Feed temper-
ature setpoint
0 – 90 °C
The current target temperature of the heat generator is displayed in °C.
-
0.1 °C
S
S
Average ext.
temperature
-39 – 50 °C
The current outside temperature is displayed in °C.
0.1 °C
S
S
Hot water
temperature
current
0 – 100 °C
The current temperature of the hot water storage tank is displayed in °C. If
no hot water function is activated, "- - -" is displayed.
-
0.1 °C
S
S
Hot water
temperature
setpoint
10 – 70 °C
The current target temperature for domestic hot water preparation is dis-
played in °C. If no hot water function is activated, "- - -" is displayed. Here,
the current target value is always the maximum value of all requests relev-
ant for this hot water circuit.
-
0.1 °C
S
S
Current return
flow temperat-
ure
0 – 100 °C
The current return flow temperature of the heat generator is displayed in
°C. If no respective sensor is connected to the heat generator, "- - -" is dis-
played.
-
0.1 °C
S
S
Current
volume flow
0 - 5100 l/h
The filtered value of the current volume flow is displayed.
-
l/h
S
S
Feed temper-
ature HC cur-
rent
0 – 100 °C
The temperature of the direct HC (t
V2
is displayed with active heating sup-
port, otherwise t
V1
) in °C.
-
0.1 °C
S
S
Feed temper-
ature HC set-
point
0 – 90 °C
The (feed) target temperature of the direct HC is displayed in °C.
-
0.1 °C
S
S
Status heat
circulation
pump
Off
The current status of the internal circulation pump of the heat generator is
displayed.
-
-
S
S
On
Mixer Position
-
Only 5xx: The current position of the 3UVDHW 3-way mixing valve in % is
displayed.
-
1%
S
S
Heat gener-
ator type
-
The configured type of the heat generator is displayed.
-
-
S
S
Software Nr
B1/U1
-
The software and version of the operating unit are displayed.
-
-
S
S
Software no.
controller
-
The software number and version of the control PCB are displayed.
-
-
S
S
Tab. 7-28
Parameter in menu: "Values"