background image

09/09/2004 - 66402800

excellence in hot water

Installation, operating and
maintenance instructions

E-Tech 09 - 15
Single phase

E-Tech 22 - 28 - 36
Tri phase

Summary of Contents for 9

Page 1: ...09 09 2004 66402800 excellence in hot water Installation operating and maintenance instructions E Tech 09 15 Single phase E Tech 22 28 36 Tri phase...

Page 2: ...data of model 22 28 36 9 MOUNTING 10 Dimensions 10 Wall mounting 10 Installation room 10 INSTALLATION 11 Disassembling 11 Heating connection 12 Heating connection DHW Y plan 12 Heating connection DHW...

Page 3: ...re not specified by the manufacturer The manufacturer reserves the right to change the technical characteristics and specification of its products without notice the availability of certain versions a...

Page 4: ...and power level switches CONNECTION The boiler is suitable for connection to most heating and hot water systems with a maximum working pressure of 3bar and a maximum temperature of 85 C It can also be...

Page 5: ...ating return not used Heating return Automatic air vent Expansion vessel Valve of expansion vessel Heating out Manual reset high limit pressure gauge Expansion vessel connection Circulating pump Heati...

Page 6: ...emperature If the boiler is not in regular daily use during cold periods it is recommended that it be fitted with a frost sensing thermostat to override the timeclock and prevent the system from freez...

Page 7: ...n working pressure bars 3 3 3 3 3 Max working pressure bars 10 10 10 10 10 Expansion vessel capacity Litres 13 13 13 13 13 Water capacity Litres 6 6 5 3 3 Number of elements 3 x 2 kW 2 x 2 4 kW 2 x 2...

Page 8: ...1 4 7 Single phase 5 6 kW Terminals 1 and 2 shunted Terminal 3 L1 A 12 12 24 Terminals 3 4 5 and 6 shunted Terminal 1 N A 12 12 24 Relay K3 disactivated Power kW 2 8 2 8 5 6 Single phase 4 2 kW Termin...

Page 9: ...nted Terminal 1 N A 20 8 20 8 41 6 Relay K3 disactivated Power kW 4 8 4 8 9 6 Single phase 7 2 kW Terminals 1 and 2 shunted Terminal 3 L1 A 20 8 10 4 31 2 Terminals 3 4 and 5 shunted Terminal 1 N A 20...

Page 10: ...2 Terminal 1 N A 0 0 0 Power kW 14 4 7 2 21 6 Tri phase 14 4 kW Terminals 3 and 4 shunted Terminal 2 L1 A 10 4 10 4 20 8 Terminals 5 and 6 shunted Terminal 3 L2 A 10 4 10 4 20 8 Relay K3 disactivated...

Page 11: ...e fitted CONNECTING TO THE SYSTEM The boiler is designed to operate on a sealed system ie no open vent or feed and expansion cistern Hot water expansion within the system is taken up by the internal 1...

Page 12: ...s to hydraulic connections 1 undo screws 2 tilt panel towards you and lift clear remove the top cover 3 loosen screws of the control panel 4 turn up the control panel 5 block the control panel with th...

Page 13: ...5 4 3 2 1 39 38 37 36 3 5 3 4 3 3 3 2 31 29 2 8 2 7 2 6 2 5 2 4 2 3 2 2 21 19 1 8 1 7 1 6 1 5 1 4 1 3 1 2 11 9 8 7 6 5 4 3 2 1 15 15 13 14 13 14 11 12 11 12 HEATING CONNECTION HEATING CONNECTION DHW...

Page 14: ...ccordance with the current IEE Wiring Regulations Isolation device must be provided with a minimum contact clearance of 3mm The MCB must be readily accessible and adjacent to the appliance 7 8 7 8 5 6...

Page 15: ...400 V Neutral ELECTRIC CONNECTION MODELS 22 28 36 SIZING OF SUPPLY WIRES the supply wires are sized depending of the type and current of the MCB this last is firstly sized depending of the nominal cu...

Page 16: ...Pink r Red v Violet w White y Yellow A ON OFF switch B Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Bo...

Page 17: ...w White y Yellow A ON OFF switch B Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Boiler thermostat 60 8...

Page 18: ...Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Boiler thermostat 60 85 C I Boiler thermostat 53 78 C J P...

Page 19: ...bk or or r 8 4 kW Type 9 MONO PHASE 7 kW 5 6 kW 4 2 kW 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17...

Page 20: ...RING MODEL 22 21 6 kW Type 22 TRI PHASE 14 4 kW 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 17 18 17 18 17 18 17 18 3 x b 3 x or 2 x bk 1 x bk 2 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk...

Page 21: ...8 28 8 kW Type 28 TRI PHASE 21 6 kW 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 19 20 19 20 19 20 19 20 4 x b 4 x or 3 x bk 1 x bk 3 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk b K4 or r b...

Page 22: ...1 x bk 5 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk b K3 or r bk b or r bk b K4 or r bk b or r bk b K5 or r bk b or r bk b K6 or r bk b or r bk b 36 kW Type 36 TRI PHASE 30 kW 1 N 2 L1 3 L...

Page 23: ...or clarity During installation the earth wires from each component connect to terminal 3 in the wiring centre E bk black br brown r red w white y yellow o orange b blue v violet p pink gr grey CABLE C...

Page 24: ...earth wires from each component connect to terminal 3 in the wiring centre E bk black br brown r red w white y yellow o orange b blue v violet p pink gr grey CABLE COLOUR CODES gr b b b o 1 2 C HW OF...

Page 25: ...on the power levels switch stage 2 after a short delay the second stage contactors will energise Note the power stage delay timer settings should be verified as shown in item 4 under Commissioning El...

Page 26: ...25 REMOVAL THE HEATING ELEMENTS 2 1 3...

Page 27: ...1474421 21474421 21474421 21474421 21474421 A05 Control panel ABS 497B1025 497B1025 497B1025 497B1025 497B1025 A06 Wall mounting 21480069 21480069 21480069 21480069 21480069 A07 Body heating 30537482...

Page 28: ...017 B14 Combined T and pressure gauge 40mm 54763012 54763012 54763012 54763012 54763012 B15 Red alarm indicator 10mm 240V 54766001 54766001 54766001 54766001 54766001 B16 Control thermostat 2 Stages 5...

Page 29: ...28 SPARE PARTS B01 B02 B03 B04 B05 B06 B07 B08 B09 B10 B11 B12 B13 B14 B16 B17 B18 B19 B21 B22 B23 B24 B15 B20 B25 B26 B27 B28 B29 B30...

Page 30: ...29...

Page 31: ......

Page 32: ...USA TEL 1 856 228 8881 FAX 1 856 228 3584 E MAIL sales triangletube com excellence in hot water www acv world com ARGENTINA TECNOPRACTICA ALFEREZ BOUCHARD 4857 1605 CARAPACHAY BUENOS AIRES TEL 54 11 4...

Reviews: