SPARE PARTS

Accessories

09

15

22

28

36

B01 Base for relay

54428195

54428195

54428195

54428195

54428195

B02 Control circuit “Siemens”

54766015

54766015

54766015

54766015

54766015

B03 Relay Siemens 3TG

54452082

54452082

54452082

54452082

54452082

B04 Timer “Crouset”

54428192

54428192

54428192

54428192

54428192

B05 Blocking

54452092

54452092

54452092

54452092

54452092

B06 Terminal WKN 16/U blue

54767014

54767014

54767014

54767014

54767014

B07 Terminal 16 mm

2

WKN 16/U

54428179

54428179

54428179

54428179

54428179

B08 Terminal end APN 16 mm

2

54428091

54428091

54428091

54428091

54428091

B09 Terminal WKN10 sl/u

54428155

54428155

54428155

54428155

54428155

B10 Shunt IVBWKN 16-2

54428278

54428278

54428278

54428278

54428278

B11 Control terminal block

54767015

54767015

54767015

54767015

54767015

B12 Green switch

54766016

54766016

54766016

54766016

54766016

B13 Yellow switch

54766017

54766017

54766017

54766017

54766017

B14 Combined T° and pressure gauge Ø 40mm

54763012

54763012

54763012

54763012

54763012

B15 Red alarm indicator Ø 10mm / 240V

54766001

54766001

54766001

54766001

54766001

B16 Control thermostat 2 Stages

54764017

54764017

54764017

54764017

54764017

B17 Button thermostat

54764021

54764021

54764021

54764021

54764021

B18 Manual reset high limit thermostat 103°C

54764009 

54764009

54764009

54764009

54764009

B19 Cable gland (PG29)

54428113

54428113

54428113

54428113

54428113

B20 Brass pocket

63438003 

63438003

63438003

63438003

63438003

B21 Heating element 2 x 1.4 kW

54428183

-

-

-

-

B22 Heating element 2 x 2.4 kW

-

54428182

54428182

54428182

-

B23 Heating element 3 x 2 kW

-

-

-

-

54428204

B24 Water pressure switch

557D3011

557D3011

557D3011

557D3011

557D3011

B25 Circulating pump

557A4009

557A4009

557A4009

557A4009

557A4009

B26 Pressure safety valve 3 bars Ø 1/2”

55426017

55426017

55426017

55426017

55426017

B27 Automatic air vent

55445007

55445007

55445007

55445007

55445007

B28 Flexible tube

B29 Expansion vessel 10 Litres

557A7006

557A7006

557A7006

557A7006

557A7006

B30  Complete control panel

24614142

24614142

24614143

24614144

24614145

Summary of Contents for 9

Page 1: ...09 09 2004 66402800 excellence in hot water Installation operating and maintenance instructions E Tech 09 15 Single phase E Tech 22 28 36 Tri phase...

Page 2: ...data of model 22 28 36 9 MOUNTING 10 Dimensions 10 Wall mounting 10 Installation room 10 INSTALLATION 11 Disassembling 11 Heating connection 12 Heating connection DHW Y plan 12 Heating connection DHW...

Page 3: ...re not specified by the manufacturer The manufacturer reserves the right to change the technical characteristics and specification of its products without notice the availability of certain versions a...

Page 4: ...and power level switches CONNECTION The boiler is suitable for connection to most heating and hot water systems with a maximum working pressure of 3bar and a maximum temperature of 85 C It can also be...

Page 5: ...ating return not used Heating return Automatic air vent Expansion vessel Valve of expansion vessel Heating out Manual reset high limit pressure gauge Expansion vessel connection Circulating pump Heati...

Page 6: ...emperature If the boiler is not in regular daily use during cold periods it is recommended that it be fitted with a frost sensing thermostat to override the timeclock and prevent the system from freez...

Page 7: ...n working pressure bars 3 3 3 3 3 Max working pressure bars 10 10 10 10 10 Expansion vessel capacity Litres 13 13 13 13 13 Water capacity Litres 6 6 5 3 3 Number of elements 3 x 2 kW 2 x 2 4 kW 2 x 2...

Page 8: ...1 4 7 Single phase 5 6 kW Terminals 1 and 2 shunted Terminal 3 L1 A 12 12 24 Terminals 3 4 5 and 6 shunted Terminal 1 N A 12 12 24 Relay K3 disactivated Power kW 2 8 2 8 5 6 Single phase 4 2 kW Termin...

Page 9: ...nted Terminal 1 N A 20 8 20 8 41 6 Relay K3 disactivated Power kW 4 8 4 8 9 6 Single phase 7 2 kW Terminals 1 and 2 shunted Terminal 3 L1 A 20 8 10 4 31 2 Terminals 3 4 and 5 shunted Terminal 1 N A 20...

Page 10: ...2 Terminal 1 N A 0 0 0 Power kW 14 4 7 2 21 6 Tri phase 14 4 kW Terminals 3 and 4 shunted Terminal 2 L1 A 10 4 10 4 20 8 Terminals 5 and 6 shunted Terminal 3 L2 A 10 4 10 4 20 8 Relay K3 disactivated...

Page 11: ...e fitted CONNECTING TO THE SYSTEM The boiler is designed to operate on a sealed system ie no open vent or feed and expansion cistern Hot water expansion within the system is taken up by the internal 1...

Page 12: ...s to hydraulic connections 1 undo screws 2 tilt panel towards you and lift clear remove the top cover 3 loosen screws of the control panel 4 turn up the control panel 5 block the control panel with th...

Page 13: ...5 4 3 2 1 39 38 37 36 3 5 3 4 3 3 3 2 31 29 2 8 2 7 2 6 2 5 2 4 2 3 2 2 21 19 1 8 1 7 1 6 1 5 1 4 1 3 1 2 11 9 8 7 6 5 4 3 2 1 15 15 13 14 13 14 11 12 11 12 HEATING CONNECTION HEATING CONNECTION DHW...

Page 14: ...ccordance with the current IEE Wiring Regulations Isolation device must be provided with a minimum contact clearance of 3mm The MCB must be readily accessible and adjacent to the appliance 7 8 7 8 5 6...

Page 15: ...400 V Neutral ELECTRIC CONNECTION MODELS 22 28 36 SIZING OF SUPPLY WIRES the supply wires are sized depending of the type and current of the MCB this last is firstly sized depending of the nominal cu...

Page 16: ...Pink r Red v Violet w White y Yellow A ON OFF switch B Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Bo...

Page 17: ...w White y Yellow A ON OFF switch B Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Boiler thermostat 60 8...

Page 18: ...Manual reset high limit thermostat C Water pressure switch D Alarm indicator E Switch indicator F Optional room thermostat G Cirluating pump H Boiler thermostat 60 85 C I Boiler thermostat 53 78 C J P...

Page 19: ...bk or or r 8 4 kW Type 9 MONO PHASE 7 kW 5 6 kW 4 2 kW 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 1 N 2 3 L 4 5 6 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17 18 17...

Page 20: ...RING MODEL 22 21 6 kW Type 22 TRI PHASE 14 4 kW 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 17 18 17 18 17 18 17 18 3 x b 3 x or 2 x bk 1 x bk 2 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk...

Page 21: ...8 28 8 kW Type 28 TRI PHASE 21 6 kW 1 N 2 L1 3 L2 4 5 L3 6 1 N 2 L1 3 L2 4 5 L3 6 19 20 19 20 19 20 19 20 4 x b 4 x or 3 x bk 1 x bk 3 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk b K4 or r b...

Page 22: ...1 x bk 5 x r 1 x r K1 or r bk b or r bk b K2 Or r Bk b or r bk b K3 or r bk b or r bk b K4 or r bk b or r bk b K5 or r bk b or r bk b K6 or r bk b or r bk b 36 kW Type 36 TRI PHASE 30 kW 1 N 2 L1 3 L...

Page 23: ...or clarity During installation the earth wires from each component connect to terminal 3 in the wiring centre E bk black br brown r red w white y yellow o orange b blue v violet p pink gr grey CABLE C...

Page 24: ...earth wires from each component connect to terminal 3 in the wiring centre E bk black br brown r red w white y yellow o orange b blue v violet p pink gr grey CABLE COLOUR CODES gr b b b o 1 2 C HW OF...

Page 25: ...on the power levels switch stage 2 after a short delay the second stage contactors will energise Note the power stage delay timer settings should be verified as shown in item 4 under Commissioning El...

Page 26: ...25 REMOVAL THE HEATING ELEMENTS 2 1 3...

Page 27: ...1474421 21474421 21474421 21474421 21474421 A05 Control panel ABS 497B1025 497B1025 497B1025 497B1025 497B1025 A06 Wall mounting 21480069 21480069 21480069 21480069 21480069 A07 Body heating 30537482...