4
Function
Operating Instructions
14
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
Temporary heating
program
Setting/activation in
the menu
Information
Party
Time program
Away
Holiday
Vacation
Screed
Configuration
Tab. 4-2
Overview of temporary time programs
INFORMATION
If a temporary heating program (Party, Away, Holiday, Va-
cation, Screed) is started during the selected operating
mode, control is carried out primarily according to the set-
tings for this time program.
4.2
User
[→ Main menu → User]
The most important target temperatures and functions are set for the
user in this menu.
4.2.1
Room temperature setpoint setting
[→ Main menu → User → Room]
The room temperature setpoints for room heating in Heating mode
are defined in this menu. The available setpoints (1-3) belong to the
respective cycle (1-3) of the [Heating circuit automatic 1] and [Heat-
ing circuit automatic 2] time programs.
Further explanations and possible settings for this menu can be
found in
.
4.2.2
Room temperature reduced setting
[→ Main menu → User → Reduce]
The room target temperatures for room heating in Reduced mode
are defined in this menu. The reduced operation is carried out by the
"Reduce" operating mode or by the [Heating circuit automatic 1] and
[Heating circuit automatic 2] time programs.
Further explanations and possible settings for this menu can be
found in
.
4.2.3
Room temperature absence setting
[→ Main menu → User → Absent]
The room target temperature for room heating in Absence mode are
defined in this menu. The absence operation is carried out by the
[Away] or [Vacation] time programs.
Further explanations and possible settings for this menu can be
found in
.
4.2.4
Hot water temperature setpoint setting
[→ Main menu → User → Hot water]
The hot water target temperatures for domestic hot water prepara-
tion are defined in this menu. The available setpoints (1-3) belong to
the respective cycle (1-3) of the [Hot water automatic 1] and [Hot wa-
ter automatic 2] time programs.
Further explanations and possible settings for this menu can be
found in
.
4.2.5
Unscheduled domestic hot water
generation
[→ Main menu → User → 1x load]
By starting this function, the hot water can be heated up to the [Hot
water temp. setpoint 1] target temperature at any time. The heating
up is carried out with priority and independent of other heating pro-
grams. After this temporary function has elapsed, the control unit
automatically jumps back to the previously active operating mode.
Possible settings for this menu can be found in
.
4.3
Time Program
[→ Main menu → Time program]
Various freely adjustable permanent time programs are available for
convenient and individual room and hot water temperature control.
Temporary time programs are also available, which override the per-
manent time programs or the currently set operating mode for the
duration of their validity.
4.3.1
Temporary time programs
INFORMATION
The following temporary time programs can be cancelled
at any time due to the manual changing of the operating
mode.
Party
[→ Main menu → Time program → Party]
The program runs from activation until the end of the set period. Dur-
ing this time, the HC is controlled to the temperature set in the
[Room temperature setpoint 1] parameter. If the [Automatic 1] or
[Automatic 2] time program is active, the heating cycle is extended
or started prematurely. The domestic hot water preparation is not af-
fected.
Away
[→ Main menu → Time program → Absent ]
The program runs from activation until the end of the set period. Dur-
ing this time, the HC is controlled to the room target temperature in
the [Room temperature absence] parameter. The domestic hot water
preparation is not affected.
Vacation
[→ Main menu → Time program → Holiday]
A calendar function can be used to enter a time period of absence.
During this time, the HC is continuously controlled (24 h per day) to
the room target temperature set in the [Room temperature absence]
parameter. This program is not started if the [Standby] operating
mode is active on the set start date.
Holiday
[→ Main menu → Time program → Public holiday]
A calendar function can be used to enter a time period of presence.
During this time, regulation is carried out exclusively according to the
settings for "Sunday" in [Heating circuit automatic 1] and [Hot water
automatic 1].
4.3.2
Permanent time programs
For the connected HCs and the storage tank charging circuit, time
programs control the HC and hot water temperatures or the operat-
ing times of the circulation pump according to the specified switching
cycles. The switching cycles are saved in time blocks for which dif-
ferent target temperatures can be set.
The saved time program can be changed at any time. For a better
overview, it is recommended to write down and safely store the pro-
grammed switching cycles (