Summary of Contents for CORVEC CELT TS

Page 1: ...chaffoteauxltd CORVEC CELTTS EN26 CONFORMS WITH EUROPEAN STANDARD BS5386Ptl installation servicing requirements ...

Page 2: ...ure 1F LP Remote model High pressure 2F HP Remote model Low pressure 2F LP The installation of the heater must be in accordance with the relevant requirements of the Gas Safet shouY Regulations building Regulations and the Byelaws of the local Water Undertaking It d be in accordance also with any relevant requirements of the local gasregion and local au thorny and the relevant recommendations of t...

Page 3: ... mm 150 l hr 250 l hr 0 45 bar 6 5 psi 10 0 bar 150 psi 1 3 m 4 26 ft 24 0 m 80 ft 38 385 Btu h 29 600 Btu h 15 35 ft3 h 1 78 lbs h 11 99 ft3 h 1 81 lbs h 8inwg 10inwg 0 55 gpm 0 92 gpm Note the minimum water pressure is for the correct operation of the heater only An additional allowance must be made for the resistance of the pipework and fittings Waterinlet Wateroutlet Gas Height Height with dra...

Page 4: ... and must not be used on any other Gas This heater is designed for installation over the sink to deli ver hot water either through a swivel spout or to a hot water tap at a sink or basin The remote model is designed for direct connection to the tap These heaters must NOT be connected to a bath hot water draw off on run continuously for more than 5 minu tes SeeBS 5546 4 ...

Page 5: ...actory operation of the heater at a minimum flow of 0 44 g p m Fit spout 1 F model The hot water draw off may be connected directly to the base of the heater using 12 mm copper pipe and the outlet bend provided 2 F model FITTING OF DRAUGHT DIVERTER Fit clip to flue deflector using nut and bolt provided Fig 1 Where it is necessary to tit a draught diverter remove the flue deflector Fit the front fa...

Page 6: ...ilot tube clamping screw A and remove the clamp and tube fig 2 Blow through the tube to remove any dust Remove the burner seesection 2 Unscrew the knurled pilot burner outer ring A fig 3 Unscrew the pilot body B with a 15 mm spanner or an ad justable spanner It may be necessaryto remove the heating body Clean by blowing or washing in water Do not clean the holes with a wire Blow any dust out of th...

Page 7: ...B on the water section fold Unscrew the six screws C holding the water section to the gassection Remove the water section complete with the diaphragm and bearing plate If the gas rate is not correct check the working pressure at the pressure test point on the test point on the storage cylin der and adjust the pressure regulator in accordance with the data in Table 1 the gasinstallation should be e...

Page 8: ...thermocouple Changevalve Check at inlet to heater Check pressure at meter MAIN BURNER DOES NOT LIGHT i Gasservice tap not open fully ii Gaspressurelow iii Water rate low iv Gasvalve push rod jammed v Diaphragm vi Gastap vii Injector size Open fully Check at manifold and at inlet with heater running Check ifwater rate is sufficient page3 Clean rod Change diaphragm Check operation of User s gas cont...

Page 9: ...let pressure too high for governor iii Faulty flue REMEDY Purge line Clean push rod Changevalve facing Replace water stopcock or pin down jumper Vent or remove Clean water section Remove heating body and clean Check manifold Check gastype and injector Purge Check pressure Check flue HEATER SMELLS WHEN NEW HIGH WATER FLOW i Scale i Water service tap partly closed ii Low water pressure iii Water gov...

Page 10: ... gasconnection to gassection Thermocouple Electrode and lead assembly Thermoelectric valve Piezo cartridge Washer Water service cock _ _ Washer Diaphragm Tap washers Nut water inlet bend Water inlet bend CHAFFOTEAUX LIMITED Concord House Brighton Road Salfords Redhill SURREY RHl 5 DX HORLEY 02934 72744 Makers Pt No 39987 34392 32120 32119 44172 61745 3990 3989 22063 30 36938 22833 10 37830 34239 3...

Page 11: ...Notes ...

Page 12: ...ESPOOS ...