7
Parameter settings
Operating Instructions
30
Daikin RoCon+ HP
Daikin Controller RoCon+ HP
008.1444299_01 – 09/2018 – EN
7.3
User
[→ Main menu → User]
7.3.1
Menu: Room temperature target
[→ Main menu → User → Room]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Room tem-
perature set-
point 1
5 - 40 °C
Target value of the room temperature in °C, which is valid for the 1st
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
20 °C
0.5 °C
E
E
Room tem-
perature set-
point 2
5 - 40 °C
Target value of the room temperature in °C, which is valid for the 2nd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
20 °C
0.5 °C
E
E
Room tem-
perature set-
point 3
5 - 40 °C
Target value of the room temperature in °C, which is valid for the 3rd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
20 °C
0.5 °C
E
E
Tab. 7-6
Parameter in menu: "Room temperature target"
7.3.2
Menu: Room temperature reduced
[→ Main menu → User → Reduce]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Room tem-
perature re-
duced
5 - 40 °C
Target value of the reduced room temperature in °C, which is valid for the
[Automatic 1] and [Automatic 2] time programs.
15 °C
0.5 °C
E
E
Tab. 7-7
Parameter in menu: "Room temperature reduced"
7.3.3
Menu: Room temperature absent
[→ Main menu → User → Absent]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Room tem-
perature ab-
sence
5 - 40 °C
Target value of the reduced room temperature in °C, which is valid for the
[Away] + [Vacation] time programs.
15 °C
0.5 °C
E
E
Tab. 7-8
Parameter in menu: "Room temperature absent"
7.3.4
Menu: Hot water temperature, target
[→ Main menu → User → Hot water]
Parameters
Setting range
Min / Max
Description
Factory
setting
Incre-
ment
Access
BE HF
Hot water
temp. setpoint
1
35 – 70 °C
Target value of the hot water temperature in °C, which is valid for the 1st
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
48 °C
0.5 °C
E
E
Hot water
temp. setpoint
2
35 – 70 °C
Target value of the hot water temperature in °C, which is valid for the 2nd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
48 °C
0.5 °C
E
E
Hot water
temp. setpoint
3
35 – 70 °C
Target value of the hot water temperature in °C, which is valid for the 3rd
switching time cycle of the [Automatic 1] and [Automatic 2] time programs.
48 °C
0.5 °C
E
E
Tab. 7-9
Parameter in menu: "Hot water temperature, target"