![background image](http://html.mh-extra.com/html/daikin/2mks40g2v1b/2mks40g2v1b_service-manual_501075286.webp)
Outdoor Unit
SiBE12-816_D
275
Removal Procedure
1.2
Removal of Electrical Box
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Disconnect the
connecting wires.
When reassembling, fasten
the wires with screws on the
terminal board.
1
Remove the 2
grounding screws.
Remove the 2 screws
and remove the wiring
fixture.
Then remove all the
screws to disconnect
the power supply
cables and the
connecting wires.
2. Remove the electrical
box.
1
Release the outdoor
temperature thermistor.
2
Lift up the guard net
and remove it.
4
4
P
Room A
Room B
Power supply
(R7573)
Grounding
screws
Wiring
fixture
(R7208)
Outdoor temperature thermistor
Guard net
(R7209)