RA Indoor Unit
SiBE12-816_D
105
Operation Manual
12
To change the temperature setting
Press .
COOL operation
HEAT operation
AUTO operation
DRY or FAN operation
18-32˚C
10-30˚C
18-30˚C
Operating conditions
Recommended temperature setting
• For cooling: 26-28˚C
• For heating: 20-24˚C
Tips for saving energy
.
Notes on the operating conditions
MODE
Operating conditions
If operation is continued out of this range
COOL
HEAT
• A safety device may work to stop the operation.
DRY
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
• The displayed items on the LCD will change whenever either one of the buttons is
pressed.
The temperature setting is
not variable.
Press to raise the temperature and press to lower the
temperature.
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks.
• The outdoor unit consumes some power to have its electric components work even while it is not operating.
Connecting outdoor unit RXG25/35: 1-15W
Other outdoor units: 15-20W
The outdoor unit consumes 40 to 55W of power at the time of compressor preheating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
Outdoor temperature : <2/3/4/5MXS> –10-46˚C
<RXG> –10-46˚C
Indoor temperature : 18-32˚C
Indoor humidity : 80% max.
Outdoor temperature : <2/3/4/5MXS> –10-46˚C
<RXG> –10-46˚C
Indoor temperature : 18-32˚C
Indoor humidity : 80% max.
Outdoor temperature : <2MXS> –10-24˚C
<3/4/5MXS> –15-24˚C
<RXG> –15-24˚C
Indoor temperature : 10-30˚C
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the
outdoor unit only.)
• Condensation may occur on the indoor unit and drip.