![background image](http://html.mh-extra.com/html/daikin/2mks40g2v1b/2mks40g2v1b_service-manual_501075332.webp)
Piping Diagrams
SiBE12-816_D
321
Appendix
1.2
Outdoor Unit
1.2.1 Cooling Only
2MKS40GV1B, 2MKS40G2V1B
2MKS50GV1B, 2MKS50G2V1B
EV
A
M
7.9CuT
7.9CuT
9.5CuT
ROOM A
(9.5 CuT)
6.4CuT
MUFFLER
COMPRESSOR
ROOM B
(9.5 CuT)
COOLING
OUTDOOR UNIT
PROPELLER FAN
MOTOR OPERATED VALVE
MUFFLER
7.0CuT
9.5CuT
FAN MOTOR
6.4CuT
9.5CuT
9.5CuT
ACCUMULATOR
6.4CuT
REFRIGERANT FLOW
9.5CuT
9.5CuT
MOTOR OPERATED VALVE
BRANCH
PIPE
6.4CuT
6.4CuT
4.8CuT
MUFFLER
MUFFLER
9.5CuT
6.4CuT
4.8CuT
EV
B
HEAT EXCHANGER
MUFFLER
9.5CuT
9.5CuT
7.0CuT
MUFFLER
ROOM B
(6.4 CuT)
ROOM A
(6.4 CuT)
BRANCH
PIPE
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
BRANCH
OUTDOOR TEMPERATURE
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID PIPE
THERMISTOR
LIQUID PIPE
THERMISTOR
LIQUID LINE
STOP VALVE
LIQUID LINE
STOP VALVE
FIELD
PIPING
LIQUID
DISCHARGE PIPE
THERMISTOR
BRANCH
PIPE
FIELD
PIPING
GAS
BRANCH
PIPE
GAS PIPE
THERMISTOR
GAS PIPE
THERMISTOR
GAS LINE
STOP VALVE
GAS LINE
STOP VALVE
FOUR WAY VALVE
NORMALLY:OFF
3D055809C
M
7.9CuT
EV
A
7.9CuT
6.4CuT
4.8CuT
6.4CuT
6.4CuT
FILTER
9.5CuT
ACCUMULATOR
COOLING
9.5CuT
7.9CuT
9.5CuT
9.5CuT
FAN MOTOR
PROPELLER FAN
9.5CuT
COMPRESSOR
OUTDOOR UNIT
6.4CuT
HEAT EXCHANGER
EV
B
MUFFLER
4.8CuT
9.5CuT
9.5CuT
9.5CuT
MOTOR OPERATED VALVE
FILTER
MUFFLER
MUFFLER
REFRIGERANT FLOW
MOTOR OPERATED VALVE
6.4CuT
9.5CuT
7.9CuT
FIELD
PIPING
LIQUID
FIELD
PIPING
GAS
LIQUID LINE
STOP VALVE
LIQUID LINE
STOP VALVE
LIQUID PIPE
THERMISTOR
LIQUID PIPE
THERMISTOR
BRANCH
PIPE
OUTDOOR TEMPERATURE
THERMISTOR
MUFFLER
WITH
BRANCH
HEAT EXCHANGER
THERMISTOR
BRANCH
PIPE
DISCHARGE PIPE
THERMISTOR
BRANCH
PIPE
GAS PIPE
THERMISTOR
GAS PIPE
THERMISTOR
GAS LINE
STOP VALVE
GAS LINE
STOP VALVE
FOUR WAY VALVE
NORMALLY:OFF
ROOM A
(9.5 CuT)
ROOM B
(12.7 CuT)
ROOM A
(6.4 CuT)
ROOM B
(6.4 CuT)
3D057468C