![background image](http://html.mh-extra.com/html/daikin/2mks40g2v1b/2mks40g2v1b_service-manual_501075288.webp)
Outdoor Unit
SiBE12-816_D
277
Removal Procedure
7
Disconnect the
connectors [S20],
[S21], [S80].
[S20]: electronic expansion
valve coil for room A
(white)
[S21]: electronic expansion
valve coil for room B (red)
[S80]: four way valve coil
8
Disconnect the relay
connector for the
compressor.
9
Disconnect the 2
connectors for the
reactor.
10
Release the discharge
pipe thermistor.
Meet the edge of the
thermistor and the clip.
Be careful not to lose the clip
for the thermistor.
Step
Procedure
Points
[S20]
[S21]
[S80]
(R12532)
(R12533)
(R12534)
Discharge pipe thermistor
(R12535)