![background image](http://html.mh-extra.com/html/daikin/2mks40g2v1b/2mks40g2v1b_service-manual_501075292.webp)
Outdoor Unit
SiBE12-816_D
281
Removal Procedure
4
Release the earth wire
from the hook.
5
Remove the 2 screws
and detach the clip to
remove the radiation
shield plate.
Step
Procedure
Points
(R12541)
Temperature fuse harness
Radiation shield plate
Clip
(R7600)
Clip
Hole
(R7596)
Compressor
harness
(R12565)