![background image](http://html.mh-extra.com/html/daikin/2mks40g2v1b/2mks40g2v1b_service-manual_501075218.webp)
Service Check Function
SiBE12-816_D
207
Service Diagnosis
Check Method 2
1. Press the center of the TEMP button and the MODE button simultaneously to enter the
diagnosis mode.
The figure of the ten’s place blinks.
2. Press the TEMP
▲
or
▼
button and change the figure until you hear the sound of “beep” or
“pi pi”.
3. Diagnose by the sound.
★
“pi” : The figure of the ten’s place does not accord with the error code.
★
“pi pi” : The figure of the ten’s place accords with the error code but the one’s not.
★
“beep” : The both figures of the ten’s and one’s place accord with the error code.
(The figures indicated when you hear the “beep” sound are error code.
→
Refer to page 213, 214.)
4. Press the MODE button.
The figure of the one’s place blinks.
(R4272)
(R4273)
(R4274)
(R4275)
(R4276)