Instruction
SiBE12-519
88
System Configuration
To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button” to
set the clock to the present time.
Holding down “
”
or “
” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
blinks.
Turn the breaker ON
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
NOTE
Tips for saving energy
2
2
2
2
2
2
2
2
2
2
2
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
Please note
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
1.3
2
Recommended temperature setting
For cooling:26˚C – 28˚C
For heating:20˚C – 24˚C
Mode
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature: 2MK(X)S 10 to 46 ˚C
3/4MK(X)S –10 to 46 ˚C
RK(X)S –10 to 46 ˚C
RK(X)H 10 to 46 ˚C
Indoor temperature: 18 to 32 ˚C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the out-
door unit only.)
Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature: 2MXS –10 to 21 ˚C
3/4MXS –15 to 21 ˚C
RXS –15 to 21 ˚C
RXH –10 to 21 ˚C
Indoor temperature: 10 to 30 ˚C
A safety device may work to stop the operation.
DRY
Outdoor temperature: 2MK(X)S 10 to 46 ˚C
3/4MK(X)S –10 to 46 ˚C
RK(X)S –10 to 46 ˚C
RK(X)H 10 to 46 ˚C
Indoor temperature: 18 to 32 ˚C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...