3
The partition plate is
fixed to the bottom
frame with a claw.
Lift it and pull out
towards you.
Fit the claw of the partition
plate to the bottom frame
when reassembling.
4
Loosen two screws of
the partition plate.
5
Untie the fixing string
and remove the sound
blanket (side-outer).
Loosen the screw to remove
the reactor from the partition
plate.
6
Remove the sound
blanket (top).
Since the piping ports on the
sound blanket are torn
easily, remove the blanket
carefully.