Priority Room Setting
The Priority Room Setting requires initial programming during installation. Please consult your
retailer or dealer for assistance.
The room designated as the Priority Room takes priority in the following situations;
1. Operation Mode Priority
As the operation mode of the Priority Room takes precedence, the user can select a different
operation mode from other rooms.
〈
Example
〉
* Room A is the Priority Room in the examples.
When COOL mode is selected in Room A while operating the following modes in Room B,C and D :
2. Priority when POWERFUL operation is used
〈
Example
〉
* Room A is the Priority Room in the examples.
The indoor units in Rooms A,B,C and D are all operating. If the unit in Room A enters POWERFUL
operation, operation capacity will be concentrated in Room A. In such a case, the cooling (heating)
efficiency of the units in Rooms B,C and D may be slightly reduced.
3. Priority when using OUTDOOR UNIT SILENT operation
〈
Example
〉
* Room A is the Priority Room in the examples.
Just by setting the unit in Room A to SILENT operation, the air conditioner starts OUTDOOR UNIT
SILENT operation.
You don’t have to set all the operated indoor units to SILENT operation.
■
Maximum Power Input Limitation
• The Maximum Power Input Limitation needs to be set when the unit is installed.
Contact DAIKIN dealer.
• This function limits the power input of the unit to 1700W.
It is recommended for locations with low-capacity circuit breakers.
(*2)
NOTE
Operation mode in Room B, C and D
Status of Room B, C and D when the unit in Room A is in COOL mode
COOL or DRY or FAN
Current operation mode maintained
HEAT
The unit enters Standby Mode. Operation resumes when the
Room A unit stops operating.
AUTO
If the unit is set to COOL mode, operation continues. If set to
HEAT mode, it enters Standby Mode. Operation resumes when
the Room A unit stops operating.
• Cooling capacity will drop if the Maximum Power Input Limitation is used.
Priority Room Setting
NIGHT QUIET Mode
Cooling/Heating Mode Lock
Maximum Power Input Limitation
List of functions and applicable models
Function available
Function unavailable
2MKS / 2AMKS 2MXS / 2AMXS 3MKS
4MKS
3MXS
4MXS
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...