INTELLIGENT EYE Operation
“INTELLIGENT EYE” is useful for Energy Saving
Notes on “INTELLIGENT EYE”
CAUTION
Energy saving operation
• Change the temperature –2
°
C in heating / +2
°
C in cooling / +2
°
C in dry mode from set temperature.
• Decrease the air flow rate slightly in fan operation. (In FAN mode only)
• Application range is as follows.
• Sensor may not detect moving objects further than 7m away. (Check the application range)
• Sensor detection sensitivity changes according to indoor unit location, the speed of pass-
ersby, temperature range, etc.
• The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of
mirrors as passersby.
• INTELLIGENT EYE operatipon will not go on during powerful operation.
• Night set mode will not go on during you use INTELLIGENT EYE operation.
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can
detect objects it shouldn’t as well as not detect objects it should.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and
malfunction.
90˚
55˚
7m
55˚
7m
Vertical angle 90˚
(Side View)
Horizontal angle 110˚
(Top View)
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...