![background image](http://html.mh-extra.com/html/daikin/2mks40dvmb/2mks40dvmb_service-manual_501073040.webp)
SiBE12-519
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
31
1.4
Outdoor Unit
Connectors
Note:
Other Designations
PCB Detail
PCB(1):
Filter PCB
1)
S10
,
S45
,
AC1
,
AC2
Connector for terminal strip
2)
S11
,
HL1
,
HN1
Connector for control PCB
3)
S12
,
HL2
,
HN2
Connector for filter PCB
4)
S20
Connector for electronic expansion valve coil A port
5)
S21
Connector for electronic expansion valve coil B port
6)
S30
Connector for compressor
7)
S40
Connector for overload protector
8)
S70
Connector for fan motor
9)
S80
Connector for four way valve coil
10)
S90
Connector for thermistor
(outdoor air, heat exchanger, and discharge pipe)
11)
S91
Connector for thermistor (gas pipe and liquid pipe)
12)
S92
Connector for fin thermistor
13)
HC3
,
HC4
Connector for capacitor
14)
HR3
,
HR4
Connector for reactor
1)
LED A
Service monitor LED (green)
2)
FU1,FU2
Fuse (3.15A / 250V)
3)
FU3
Fuse (20A / 250V)
4)
V1
,
V2
,
V3
Varistor
5)
DB1
Diode bridge
6)
J9
Jumper for maximum power input limitation
(For cooling only type. Refer to installation manual.)
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...