![background image](http://html.mh-extra.com/html/daikin/2mks40dvmb/2mks40dvmb_service-manual_501073193.webp)
Outdoor Unit
SiBE12-519
184
Removal Procedure
Step
Procedure
Points
6
Remove the propeller
fan.
Align
mark of the propeller
fan with D-cut section of the
motor shaft when
reassembling.
7
Remove the two screws
from the fan motor.
8
Unlock the fixing claws
and release the lead
wire.
Put the lead wire through the
back of the motor when
reassembling. (so as not to
be entangled with the
propeller fan)
(R2885)
(R2888)
Lead wire
Propeller fan