Control Specification
SiBE12-519
68
Function and Control
3.14 Additional Function
3.14.1
POWERFUL Operation Mode
Compressor operating frequency and outdoor unit airflow rate are increased.
3.14.2
Voltage Detection Function
Power supply voltage is detected each time equipment operation starts.
3.14.3
Maximum Power Input Limitation
Setting
Warning
Always shut off the power supply breaker before starting.
Outline
2MKS40DVMB only
• The Maximum Power Input Limitation needs to be set when the unit is installed.
•
This function limits the power input of the unit to 1700W.
•
It is recommended for locations with low-capacity circuit breakers.
Details
• Set as follows.
1) Remove the three screws on the side and remove the top of the outdoor unit.
2) Remove the fan motor lead wire from the hook and loosen it.
3) Disengage the four tabs marked with a triangle and remove the electrical cabinet.
4) Cut the jumper (J9) of the Printed circuit board inside.
5) Go back through step 3)
→
2)
→
1). Make sure all components are well secured when doing
this.
1) Remove the three screws.
Top plate
3) Disengage the four tabs.
Electric box
Printed circuit board
4) Cut J9
J9
2) Remove the fan motor lead
wire from the hook.
Hook
Fan motor lead wire
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...