SiBE12-519
Printed Circuit Board Connector Wiring Diagram
Printed Circuit Board Connector Wiring Diagram
29
1.3
Floor / Ceiling Suspended Dual Type
Connectors
Note:
Other designations
PCB Detail
PCB(1):
Control PCB
1)
S6
Connector for swing motor (horizontal swing)
2)
S7
Connector for fan motor
3)
S21
Connector for
centralized control
4)
S24
Connector for display PCB
5)
S25
,
S27
,
S36
Connector for control PCB
6)
S26
Connector for signal receiver PCB
7)
S31
Connector for room temperature thermistor
8)
S32
Connector for heat exchanger thermistor
9)
S37
Connector for power supply PCB
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 205 for detail.
3)
SW1
Forced operation ON/OFF switch
4)
SW2
Select switch ceiling or floor
5)
LED1
LED for operation (green)
6)
LED2
LED for timer (yellow)
7)
LED3
LED for HOME LEAVE operation (red)
8)
LED A
LED for service monitor (green)
9)
FU1
Fuse
(3.15A)
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...