![background image](http://html.mh-extra.com/html/daikin/2mks40dvmb/2mks40dvmb_service-manual_501073033.webp)
Printed Circuit Board Connector Wiring Diagram
SiBE12-519
24
Printed Circuit Board Connector Wiring Diagram
1.1.2 FTK(X)S20~35C
Connectors
Note:
Other designations
1)
S1
Connector for fan motor
2)
S6
Connector for swing motor (Horizontal Flap)
3)
S7
Connector for fan motor
4)
S21
Connector for
centralized control
to 5 rooms
5)
S26
Connector for signal receiver PCB
6)
S27
Connector for control PCB
7)
S32
Connector for heat exchanger thermistor
8)
S35
Connector for INTELLIGENT EYE Sensor PCB
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 205 for more detail.
3)
SW7
Forced operation ON/OFF switch
4)
LED1
LED for operation (green)
5)
LED2
LED for timer (yellow)
6)
LED3
LED for HOME LEAVE operation (red)
7)
LED A
LED for service monitor (green)
8)
FU1
Fuse
(3.15A)
9)
RTH1
Room temperature thermistor