Troubleshooting
SiBE12-519
134
Service Diagnosis
4. Troubleshooting
4.1
Error Codes and Description
: Displayed only when system-down occurs.
Code Indication
Description
Reference
Page
System
00
Normal
—
U0
Insufficient gas
U2
Over-voltage detection
U4
Outdoor unit PCB abnormality or signal transmission circuit abnormality
UA
Unspecified voltage (between indoor and outdoor units)
UH
Anti-icing function in other rooms
Indoor
Unit
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control or high pressure control
A6
Fan motor or related
abnormality
AC motor (Wall : 20~35 C series, Duct, Floor / Ceiling)
DC motor (Wall : 20~35 D series)
C4
Heat exchanger temperature thermistor abnormality
C9
Room temperature thermistor abnormality
Outdoor
Unit
A5
Freeze-up protection control
E5
OL activation (compressor overload)
E6
Compressor lock
E7
DC fan lock
E8
Input over current detection
EA
Four way valve abnormality
F3
Discharge pipe temperature control
F6
High pressure control in cooling
H6
Position sensor abnormality
H8
CT or related abnormality
H9
Outdoor air thermistor or related abnormality
J3
Discharge pipe temperature thermistor or related abnormality
J6
Heat exchanger temperature thermistor or related abnormality
J8
Liquid pipe temperature thermistor or related abnormality
J9
Gas pipe temperature thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5
Output over current detection
P4
Radiation fin thermistor or related abnormality
Summary of Contents for 2MKS40DVMB
Page 10: ...SiBE12 519 List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 15: ...Heat Pump SiBE12 519 6 List of Functions ...
Page 29: ...Heat Pump SiBE12 519 20 Specifications ...
Page 135: ...Instruction SiBE12 519 126 System Configuration ...
Page 211: ...Outdoor Unit SiBE12 519 202 Removal Procedure ...