4.3 Type
key
DIGITS
FK
C
65
22
2
T
5
230D
Ex
S
FK
Technical pump range name
C
Single Channel
V
Free passage Vortex
65
80
100
150
Outlet diameter
22
Approximate nominal power kW x10
(a, b, c, d in case of different curve at same power)
2
4
Number of poles
T Three-phase
5
6
Tension frequency
230 D.O.L.
220-277 D.O.L.
400 D.O.L.
380-480 D.O.L.
230 Y/D
400 Y/D
220-277 Y/D
380-480 Y/D
Tension rate & Start method
blank
EX
IECEX
No explosion proof
Explosion proof
(ATEX)
Explosion proof
(IECEX)
blank
S
Sensor version (moisture sensor) NOT for Ex version
Blank
20,30,50
Cable length [m]: blank 10m
5. INSTALLATION
Before beginning installation procedures, carry out these checks:
• Does the pump correspond to order?
• Is the pump suitable for the supply voltage and frequency available at the installation site?
• Are accessories and other equipment undamaged?
When choosing the installation site, check that:
1. The voltage and frequency on the pump’s technical data plate correspond to the values of the
power supply system.
2. The electrical connection is made in a dry place, far from any possible flooding.
3. The electric system must be approved by the safety regulations in force and in good condition.
The construction of tanks, reservoirs or sinkholes where the electropump is to be housed, as well as
its positioning with respect to the level of the sewage network, are subject to standards and legal
regulations that must be respected
.
Before beginning the installation, switch off the power supply and lock the mains switch in
position 0 with a padlock to ensure that the power supply cannot be accidentally switched on.
Any external voltage connected to the pump must be switched off before working on the pump.
For further details on the accessories, see the pump technical data sheet or contact DAB
Pumps.
Fix the extra nameplate supplied with the pump to the cable end in the control cabinet.
All safety regulations must be observed at the installation site, e.g. the use of blowers for fresh-air supply to the
tank.
Do not put your hands or any tool into the pump suction or discharge port after the pump has
been connected to the power supply, unless the pump has been switched off by removing the
fuses or switching off the mains switch. It must be ensured that the power supply cannot be
accidentally switched on.
We recommend to always use Dab Pumps accessories to avoid malfunctions due to incorrect
installation.
Only use the lifting bracket for lifting the pump. Do not use it to hold the pump when in
operation. Check that the tools and equipment used for handling, lifting and lowering it into the
sinkhole are suitable for the weight to be lifted, efficient and complying with the safety laws in
force.