ENGLISH
39
English ............................................................................... 41
1.1
KEY AND GENERAL NOTES...................................................................................................................... 41
1.2
WARNINGS ................................................................................................................................................... 41
1.2.1
Skilled personnel......................................................................................................................................... 41
1.2.2
Safety .......................................................................................................................................................... 41
1.2.3
Responsibility ............................................................................................................................................. 41
1.2.4
Special warnings......................................................................................................................................... 41
1.3
APPLICATIONS ............................................................................................................................................ 42
1.4
TECHNICAL DATA AND LIMITATIONS OF USE ................................................................................... 42
1.5
ELECTRICAL CONNECTIONS TO THE ELECTRIC PUMP..................................................................... 42
1.5.1
Connection to pump for models A.D. M/T 1.0 and A.D. M/T 2.2.............................................................. 42
1.5.2
Connection to pump for models A.D. T/T 3.0 and A.D. T/T 5.5................................................................ 43
1.6
CONNECTION TO THE POWER SUPPLY LINE ....................................................................................... 43
1.7
HYDRAULIC CONNECTIONS .................................................................................................................... 44
1.8
GENERAL CHARACTERISTICS................................................................................................................. 45
1.9
KEYBOARD OPERATION ........................................................................................................................... 46
1.10
INITIAL START-UP OPERATIONS ............................................................................................................ 48
1.11
SETTING THE RATED CURRENT “rC” ..................................................................................................... 48
1.11.1
Setting the rated frequency “Fn” ............................................................................................................ 48
1.11.2
Setting the direction of rotation .............................................................................................................. 48
1.11.3
Setting the setpoint pressure................................................................................................................... 48
1.12
OPERATION: MENU ................................................................................................................................... 48
1.13
OPERATION: USER PARAMETER MENU ................................................................................................ 48
1.13.1
SP : Setting the set-point pressure (in bar). ............................................................................................ 48
1.14
OPERATION: INSTALLER PARAMETER MENU..................................................................................... 49
1.14.1
rC : Setting the rated current of the electric pump.................................................................................. 49
1.14.2
Fn : Setting the rated frequency.............................................................................................................. 49
1.14.3
rt : Setting the direction of rotation ........................................................................................................ 49
1.14.4
od : Setting the operating mode of the ACTIVE DRIVER .................................................................... 49
1.14.5
rP : Setting the fall in pressure for restarting .......................................................................................... 49
1.14.6
Ad : Setting the interconnection address ................................................................................................ 49
1.14.7
Eb : Enabling the booster ....................................................................................................................... 49
1.15
OPERATION: TECHNICAL ASSISTANCE MENU................................................................................... 50
1.15.1
tb : Setting the reaction time of the water low block .............................................................................. 50
1.15.2
t1 : Running time after low pressure signal (kiwa)................................................................................. 50
1.15.3
t2 : Delay time in event of shutdown conditions .................................................................................... 50
1.15.4
GP : Setting the gain of the PI proportional coefficient.......................................................................... 50
1.15.5
GI : Setting the gain of the PI integral coefficient.................................................................................. 50
1.15.6
FS : Setting the maximum rotation frequency of the electric pump ....................................................... 50
1.15.7
FL : Setting the minimum frequency...................................................................................................... 51
1.15.8
Ft : Setting the low flow rate threshold .................................................................................................. 51
1.15.9
CM : Exchange method .......................................................................................................................... 51
1.15.10
AE : Enabling the anti-block/anti-frost function .................................................................................... 51
1.15.11
Setup of the auxiliary digital inputs IN1; IN2; IN3 with the parameters i1; i2; i3 ................................. 51
Summary of Contents for ACTIVE DRIVER M/T 1.0
Page 275: ...270...